Teachers perception of the use on a low-cost pulse rate sensor for biology education
Jurij Dolenšek1,2, Tina Kos2, Andraž Stožer1
1Faculty of Medicine, University of Maribor, Maribor, Slovenia.
Abstract:
Information and Communication Technology (ICT) is a commonly used concept in schools, implemented in laboratory work in the form of various digital devices. We evaluated the ICT implementation in cardiovascular physiology in Slovenian primary school education. Surprisingly, we showed a relatively low acceptance rate in biology classes: only 42.8% of involved Slovenian biology teachers used a pulse rate (PR) measuring device. As a part of a Slovenian Project, students designed, developed, and manufactured a device capable of low-cost, automatic, noninvasive, and straightforward PR sampling in real time. The device was named Fingerbeeper, and teachers' perceptions of its efficacy and efficiency were evaluated in the elementary school biology lessons, comparing its ease of use with other commercially available devices: the systems from Vernier, Biopac, and the Gear Sport Samsung smartwatch. The most preferred system was the system from Vernier (36.4%), followed by the Fingerbeeper (29.1%), the system from Biopac (18.2%), and the smartwatch (16.3%). Teachers provided their opinion on the efficiency of the Fingerbeeper in terms of cost compared with the other three measurement devices. Its perception of efficiency was comparable to the other commercially available devices while having the estimated cost of only a few percent of the Biopac or Vernier systems. Considering the general low funding in the public primary schools in Slovenia, the bias toward Fingerbeeper seemed rational, outweighing the superior performance of the commercial systems. Further research and improvement of such low-cost and high-efficiency devices, also in general terms, would lead to broader acceptance and implementation of the ICT in curricula.
Related Concept Videos
Regulation of Pulse
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Special considerations while measuring pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...