Background And Aims:
Self-expandable metal stent (SEMS) placement is routinely performed in a variety of benign and malignant GI diseases. One of the most frequent adverse events after esophageal SEMS placement is stent migration. We evaluated a novel over-the-scope clip device (stentfix OTSC; Ovesco Endoscopy, Tuebingen, Germany) designed and approved for SEMS fixation.
Methods:
This single-center retrospective observational cohort study was performed to analyze stent migration rates before and after availability of the stentfix OTSC device. A cohort of patients who consecutively underwent SEMS fixation with the stentfix OTSC system (SF cohort) was compared with an historical cohort of patients who did not receive stentfix OTSC fixation or any other stent fixation method (NF cohort) before the stentfix OTSC system became available. Outcome variables including technical success, adverse events and clinical success were analyzed.
Results:
Seventy-seven patients (SF cohort, 26; NF cohort, 51) underwent esophageal SEMS implantation for malignant (69%) and benign (31%) conditions. The technical success rate of stent fixation was 100%, and no procedure-related adverse events were observed. The stent migration rate was significantly lower in the SF cohort compared with the NF cohort (8.3% vs 35.4%, P < .001), indicating a relative risk reduction of 76.5% associated with stentfix OTSC application. Stent implantation across the gastroesophageal junction was identified as a predictor of stent migration.
Conclusions:
In patients with benign or malignant gastroesophageal diseases, there was a significantly lower stent migration rate in patients managed with the stentfix OTSC system compared with those without stent fixation. The application was technically successful in all cases, and no adverse events related to clip application or removal were observed.
More Related Videos
04:05Endoscopic Vacuum Therapy for the Treatment of Anastomotic Leakage after Total Gastrectomy with Esophagojejunostomy
Published on: August 22, 2025
09:04Low-Cost Single-Port LoCoSP Device for a Transcervical Approach in Minimally Invasive Transhiatal Esophagectomy
Published on: September 11, 2021
Related Concept Videos
Endoscopic Procedures III: Video Capsule Endoscopy
Esophageal Strictures-II: Clinical Features and Management
Healthcare providers should gather a comprehensive medical history and conduct a physical examination for diagnosis. If esophageal stricture is...
Esophageal Strictures-I: Introduction
Etiology
The primary cause of esophageal strictures is long-standing gastroesophageal reflux disease (GERD), accounting for about 70 to 80% of adult cases. Chronic acid reflux can lead to injury and scarring of the esophageal lining, culminating in...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Esophageal Varices-II: Clinical Features and Management
In the initial assessment, a thorough review of the patient's medical history is vital to identify risk factors such as liver disease, alcohol...
Esophageal Varices-I: Introduction