Evaluating impact of medium variation on dose calculated through planning system in a low cost in-house phantom
Amit Saini1,2, V P Pandey3, Avtar Singh1,2
1Department of Medical Physics, Tata Memorial Center, Homi Bhabha Cancer Hospital, Sangrur, Punjab - 148001, India.
Abstract:
Purpose: In radiotherapy, accuracy in dose estimation of dose calculation methods is critical. The influence of deformity on radiation dose calculations derived by planning system is evaluated in present study. The goal of study was to create a low-cost inhomogeneous phantom for measuring absorbed dose using an Ionisation chamber and Gafchromic film, which was validated using treatment planning system (TPS) dose outcome.Methods:and Materials: The central axis dose calculations were computed using Pencil Beam Convolution algorithm (PBC), Collapsed Cone Convolution (CCC) and Monte Carlo (MC) algorithm in the Monaco treatment planning system using an In-house phantom (20 × 20 × 20cm3) made up of acrylic sheet containing water and inhomogeneous material wooden powder equivalent to lung. Phantom was scanned in Computed Tomography (CT) scanner and image set was sent to the planning workstation. The depth dose evaluations were performed using ionization chamber and Gafchromic film with same beam settings and monitor units in every setup. Following that, the calculated doses obtained from TPS and measured depth doses were compared.Results: The results was reported for photon energies 6MV, 10MV, 15MV, 6FFF and 10FFF at varying field sizes of 4 × 4 cm2, 5 × 5 cm2, 10 × 10 cm2, and 15 × 15 cm2. MC maximum dose variation predicted was 2.06% in 15MV of measured chamber dose and -2.06% of measured gafchromic film dose in 6MVFFF. CCC maximum dose variation predicted was 2.68% of measured chamber dose in 6MV and 3.31% of measured gafchromic film dose in 6MV whereas PB maximum dose variation predicted was -5.94% in 15MV of measured chamber dose and -11.6% of measured gafchromic film dose in 6MVFFF.Conclusion: Low-cost in-house phantoms can be utilised to assess point and planar doses during patient-specific quality assurance in centres that don't have accessibility to phantoms due to the high cost of commercially available tools.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses