Related Experiment Video
Updated: Oct 3, 2025

Establishment of a Simple and Effective Rat Model for Intraoperative Parathyroid Gland Imaging
Published on: August 17, 2022
Preoperative imaging in primary hyperparathyroidism: Are 11 C-Choline PET/CT and 99m Tc-MIBI/123 Iodide subtraction
Julie W Christensen1, Afefah Ismail1,2, Susanne B Søndergaard1
1Department of Nuclear Medicine, Herlev and Gentofte Hospital, Herlev, Denmark.
Objective:
Preoperative location of hyperfunctioning parathyroid glands (HPGs) is vital when planning minimally invasive surgery in patients with primary hyperparathyroidism (PHPT). Dual-isotope subtraction scintigraphy with 99m Tc-MIBI/123 Iodide using SPECT/CT and planar pinhole imaging (Di-SPECT) has shown high sensitivity, but is challenged by high radiation dose, time consumption and cost. 11 C-Choline PET/CT (faster with a lower radiation dose) is non-inferior to Di-SPECT. We aim to clarify to what extent the two are interchangeable and how often there are discrepancies.
Design:
This is a prospective, GCP-controlled cohort study.
Patients And Measurements:
One hundred patients diagnosed with PHPT were included and underwent both imaging modalities before parathyroidectomy. Clinical implications of differences between imaging findings and negative imaging results were assessed. Surgical findings confirmed by biochemistry and pathology served as reference standard.
Results:
Among the 90 patients cured by parathyroidectomy, sensitivity was 82% (95% confidence interval [CI]: 74%-88%) and 87% (95% CI: 79%-92%) for Choline PET and Di-SPECT, respectively, p = .88. In seven cases at least one imaging modality found no HPG. Of these, neither modality found any true HPGs and only two were cured by surgery. When a positive finding in one modality was incorrect, the alternative modality was correct in approximately half of the cases.
Conclusion:
Choline PET and Di-SPECT performed equally well and are both appropriate as first-line imaging modalities for preoperative imaging of PHPT. When the first-line modality fails to locate an HPG, additional preoperative imaging with the alternate modality offers no benefit. However, if parathyroidectomy is unsuccessful, additional imaging with the alternate modality has merit before repeat surgery.
More Related Videos
08:55A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...