Chromatographic and spectrophometric studies of vanadate (+V) reduction by 3-mercaptopropionic acid

Elvira Bura-Nakić1, Lucija Knežević1, Jelena Mandić2

  • 1Ruđer Bošković Institute, Department for Marine and Environmental Research, Bijenička 54, 10 000 Zagreb, Croatia.

Related Concept Videos

Redox Titration: Other Oxidizing and Reducing Agents01:26

Redox Titration: Other Oxidizing and Reducing Agents

Besides iodine, other oxidizing or reducing agents can serve as titrants in redox titrations. Common oxidizing titrants include KMnO4, cerium(IV), and K2Cr2O7. The choice of oxidizing titrants depends on factors like stability, cost, analyte strength, and reaction rate between the analyte and titrant. KMnO4 is a strong oxidizing titrant that reduces from Mn(VII) to Mn(II) in a highly acidic solution, simultaneously oxidizing the analyte to a higher oxidation state. In this case, KMnO4 acts as a...
424
Voltammetric Techniques: Cyclic Voltammetry01:10

Voltammetric Techniques: Cyclic Voltammetry

Cyclic voltammetry (CV) is an electrochemical technique used to investigate the redox properties of a chemical species. It involves measuring the current response of an electrochemical cell as a function of the applied potential. The setup for cyclic voltammetry typically consists of a working electrode, a reference electrode, and a counter electrode—all immersed in an electrolyte solution. The working electrode is where the redox reaction of interest occurs, while the reference electrode...
761
Effects of EDTA on End-Point Detection Methods01:18

Effects of EDTA on End-Point Detection Methods

Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
372
Voltammetry: Stripping Methods01:13

Voltammetry: Stripping Methods

Anodic Stripping Voltammetry (ASV), Cathodic Stripping Voltammetry (CSV), and Adsorptive Stripping Voltammetry (AdSV) are electrochemical techniques used to determine trace amounts of analytes in solution. These methods involve applying a potential to an electrode and measuring the resulting current.
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
399
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
2.2K
Composition of Polyprotic Acid Solutions as a Function of pH01:19

Composition of Polyprotic Acid Solutions as a Function of pH

Polyprotic acids of the type H2M constitute two ionizable protons. As a result, on titration with a base, they exhibit two equivalence points in the titration curve. During titration, the species H2M, HM−, and M2− will be present in the solution at different points. The fractions of H2M, HM−, and M2− present at the various instances of the titration are denoted by α0, α1, and α2, respectively.
A graph with the alpha values is plotted against the volume of...
619