Related Experiment Video
Updated: Oct 3, 2025

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Syndesmosis screw breakage: An analysis of multiple breakage locations
Josh W Vander Maten1, Matthew McCracken1, Jiayong Liu2
1Medical Student, University of Toledo, College of Medicine and Life Sciences, Toledo, OH, 43614, United States.
Introduction/Purpose:
Concerns have been raised about screw breakage within the tibia or fibula, referred to as intraosseous breakage. The purpose of this investigation is to analyze the technical aspects of syndesmotic screw placement in multiple anatomic breakage locations.
Materials:
A retrospective analysis of over 1056 patients who underwent syndesmosis fixation was completed. Demographics, screw length, width, number, height above the tibial plafond, angle, breakage location, and breakage location on the screw were collected and analyzed.
Results:
Intraosseous (IO) screw breakage (91 screws, 68 patients) was more common than clear space (CS) breakage (28 screws, 18 patients) (P = < 0.001). Within the IO group, screw breakage within the tibia (60 screws, 52 patients) was more common compared to fibula breakage (29 screws, 24 patients) (P = < 0.001).Increased BMI and the use of multiple screws were associated with IO breakage (P = .007) and CS breakage (P = .012), respectively. Increased screw angle and age were associated with fibular IO breakage (P = .021, P = .036) when compared to other IO breakage locations. Screw angle and placement showed no significant differences between compared groups (P = .629, P = .570).
Conclusion:
Syndesmosis screw breakage, overall, occurred more commonly in an IO location. When compared to IO breakage, the use of multiple syndesmosis screws is most associated with CS breakage. Increased BMI is associated with increased IO breakage when compared to CS breakage. Patients with IO screw breakage within the fibula had increased age and placed at a higher angle when compared to other IO breakage locations. No other factors related to screw placement, including the height of placement, were found to be significantly associated with location of screw breakage.
More Related Videos
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
07:35Creating Rigidly Stabilized Fractures for Assessing Intramembranous Ossification, Distraction Osteogenesis, or Healing of Critical Sized Defects
Published on: April 11, 2012
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Fixing Double-strand Breaks
Structural Joints: Fibrous Joints
Suture
All the bones of the skull, except for the mandible, are joined to each other by a fibrous joint called a suture. The fibrous connective tissue found at a suture strongly unites the adjacent skull bones and thus helps to protect the brain and form the face. In...
Structural Joints: Synovial Joints
Stress-Strain Diagram - Brittle Materials
Design of Transmission Shafts - Stress Analysis