Related Experiment Video
Updated: Oct 3, 2025

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
A novel plating technique for Ideberg type 1 A glenoid fractures: a report of five patients
Sinan Oguzkaya1, Jacobien van der Wijk2, Alexander van Tongel3
1Department of Orthopaedics and Traumatology, Sarkısla State Hospital, Sivas, Turkey.
Background:
Glenoid rim fractures are uncommon and generally associated with high complication rates. The most common treatment techniques include screw or anchor fixation. Here, we introduce a new fixation method to treat Ideberg type 1 A fractures.
Methods:
A retrospective analysis was performed on patients treated with open reduction and plate fixation for Ideberg type 1 A fractures. The active range of motion capacity of both shoulders was recorded postoperatively. Constant-Murley score and Oxford disability index scores were used as outcome tools.
Results:
Five patients (three men and two women) were evaluated; their mean age was 56 years (standard deviation (SD), 10 years). The mean follow-up period was 25 months (range, 6-69 months); all fractures healed radiologically during the follow-up period. The mean Constant-Murley score was 80.36 (SD 11.01); the mean Oxford disability index was 37 (SD 9). The subsequent flexion and external rotation of the injured shoulders were similar to those of the uninjured side (injured vs. uninjured side: flexion, 176 ± 5.4 vs. 178 ± 4.4; external rotation, 48 ± 10.9 vs. 60 ± 0). No patient showed signs of osteoarthritis, stiffness, instability, or chronic pain at the last follow-up.
Discussion:
Open reduction and internal fixation with a plate is suitable for Ideberg type 1A glenoid fractures.
More Related Videos