Accuracy of Deep Learning Echocardiographic View Classification in Patients with Congenital or Structural Heart
Felix K Wegner1, Maria L Benesch Vidal2, Philipp Niehues1
1Department of Cardiology II-Electrophysiology, University Hospital Muenster, Albert-Schweitzer-Campus 1, 48149 Muenster, Germany.
Introduction:
Automated echocardiography image interpretation has the potential to transform clinical practice. However, neural networks developed in general cohorts may underperform in the setting of altered cardiac anatomy.
Methods:
Consecutive echocardiographic studies of patients with congenital or structural heart disease (C/SHD) were used to validate an existing convolutional neural network trained on 14,035 echocardiograms for automated view classification. In addition, a new convolutional neural network for view classification was trained and tested specifically in patients with C/SHD.
Results:
Overall, 9793 imaging files from 262 patients with C/SHD (mean age 49 years, 60% male) and 62 normal controls (mean age 45 years, 50.0% male) were included. Congenital diagnoses included among others, tetralogy of Fallot (30), Ebstein anomaly (18) and transposition of the great arteries (TGA, 48). Assessing correct view classification based on 284,250 individual frames revealed that the non-congenital model had an overall accuracy of 48.3% for correct view classification in patients with C/SHD compared to 66.7% in patients without cardiac disease. Our newly trained convolutional network for echocardiographic view detection based on over 139,910 frames and tested on 35,614 frames from C/SHD patients achieved an accuracy of 76.1% in detecting the correct echocardiographic view.
Conclusions:
The current study is the first to validate view classification by neural networks in C/SHD patients. While generic models have acceptable accuracy in general cardiology patients, the quality of image classification is only modest in patients with C/SHD. In contrast, our model trained in C/SHD achieved a considerably increased accuracy in this particular cohort.
More Related Videos
12:12Echocardiographic Approaches and Protocols for Comprehensive Phenotypic Characterization of Valvular Heart Disease in Mice
Published on: February 14, 2017
09:15Displacement Analysis of Myocardial Mechanical Deformation DIAMOND Reveals Segmental Heterogeneity of Cardiac Function in Embryonic Zebrafish
Published on: February 6, 2020
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...