Related Experiment Video
Updated: Oct 3, 2025

Quantifying the Relative Thickness of Conductive Ferromagnetic Materials Using Detector Coil-Based Pulsed Eddy Current Sensors
Published on: January 16, 2020
Research on the Analytical Model of Improved Magnetic Flux Leakage Signal for the Local Stress Concentration Zone of
Lijian Yang1, Fuyin Zheng1, Ping Huang1
1College of Information Science and Engineering, Shenyang University of Technology, Shenyang 110870, China.
Abstract:
Local stress concentrations pose a significant hazard to the safe operation of pipelines. However, the classical analytical model of the magnetic flux leakage (MFL) signal is still unable to effectively quantitatively analyze and accurately evaluate the local stress concentration zone of a pipeline. In this paper, based on the Jiles-Atherton model of the magnetomechanical effect, the mathematical relationship between stress and the magnetization of ferromagnetic material under hysteresis conditions is introduced, and an improved analytical model of the MFL signal based on the magnetomechanical model is established. The influence law of stress intensity on the MFL signal in the local stress concentration zone of the pipeline is calculated and analyzed, and the theoretical calculation results are verified through experiments. Simulation and experimental results show that, considering the hysteresis condition, the stress causes a change in the hysteresis loop of the ferromagnetic material, and the magnetization strength of the material decreases with increasing stress; the effect of stress on the magnetization strength of ferromagnetic materials is most obvious when the external magnetic field is approximately 5 KA/m. The MFL signal on the surface of the local stress concentration zone of the pipe changes abruptly, and the amount of change in the axial amplitude and radial peak-to-peak value of the leakage signal of the pipe tends to increase with the increase in the stress intensity of the local stress concentration zone. A comparison of the analysis with the classical analytical model of the MFL signal shows that the improved analytical model of the MFL signal is more suitable for the quantification study of the local stress concentration zone of the pipeline.
Related Concept Videos
Stress Concentrations
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...
Magnetic Field Of A Current Loop
Stress Concentrations in Circular Shafts
Magnetostatic Boundary Conditions
Magnetic Field of a Solenoid
Consider a solenoid with 100 turns wrapped around a cylinder of...