Evaluating the Impact of Peer Review on the Completeness of Reporting in Imaging Diagnostic Test Accuracy Research

Sakib Kazi1, Robert A Frank2, Jean-Paul Salameh3,4

  • 1Faculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada.

Abstract

Insights

Peer review marginally improves reporting completeness in diagnostic test accuracy (DTA) studies but does not enhance transparency or reduce spin. Further research is needed to optimize peer review for DTA research quality.

Area of Science:

  • Medical Imaging
  • Biomedical Research
  • Scientific Publishing

Background:

  • Peer review is standard practice in medical journals, yet evidence for its impact on biomedical research quality, especially diagnostic test accuracy (DTA) studies, is limited.
  • The effectiveness of peer review in improving the reporting and transparency of DTA research remains uncertain.

Purpose of the Study:

  • To assess if peer review influences the completeness of reporting, risk of bias assessment transparency, and "spin" in imaging DTA studies.
  • The study aimed to quantify changes between manuscript submission and final publication.

Main Methods:

  • A retrospective cross-sectional study analyzed 84 DTA articles from three imaging journals (JMRI, CARJ, EuRad) published before March 31, 2020.
  • Manuscripts were evaluated using STARD 2015 and STARD for Abstracts for reporting completeness, QUADAS-2 for bias assessment transparency, and modified criteria for "spin."

Main Results:

  • Completeness of reporting based on STARD 2015 showed a statistically significant increase (0.80 items) between initial submission and final versions.
  • No significant improvements were observed in STARD for Abstracts reporting, QUADAS-2 transparency, or reduction in actual or potential "spin."

Conclusions:

  • Peer review is associated with a minor enhancement in reporting completeness for imaging DTA studies.
  • Peer review did not demonstrably improve transparency in risk of bias assessment or decrease "spin" in these studies.

Related Concept Videos

Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches01:23

Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches

Biopharmaceutical studies constitute a vital field aiming to enhance drug delivery methods and refine therapeutic approaches, drawing upon diverse interdisciplinary knowledge. In research methodologies, the choice between controlled and non-controlled studies significantly influences the study's reliability and accuracy.
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
190
Accuracy and Errors in Hypothesis Testing01:13

Accuracy and Errors in Hypothesis Testing

Hypothesis testing is a fundamental statistical tool that begins with the assumption that the null hypothesis H0 is true. During this process, two types of errors can occur: Type I and Type II. A Type I error refers to the incorrect rejection of a true null hypothesis, while a Type II error involves the failure to reject a false null hypothesis.
In hypothesis testing, the probability of making a Type I error, denoted as α, is commonly set at 0.05. This significance level indicates a 5%...
366
Receiver Operating Characteristic Plot01:15

Receiver Operating Characteristic Plot

A ROC (Receiver Operating Characteristic) plot is a graphical tool used to assess the performance of a binary classification model by illustrating the trade-off between sensitivity (true positive rate) and specificity (false positive rate). By plotting sensitivity against 1 - specificity across various threshold settings, the ROC curve shows how well the model distinguishes between classes, with a curve closer to the top-left corner indicating a more accurate model. The area under the ROC curve...
348
Computed Tomography01:10

Computed Tomography

Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
6.8K
Radiological Investigation II: MRI and Ventilation Perfusion Scan01:30

Radiological Investigation II: MRI and Ventilation Perfusion Scan

Description
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
243
Sensitivity, Specificity, and Predicted Value01:13

Sensitivity, Specificity, and Predicted Value

In healthcare diagnostics, laboratory tests play a crucial role in identifying and diagnosing a wide range of medical conditions. However, interpreting test results is not always straightforward. An abnormal test result does not always confirm the presence of a disease, just as a normal result does not guarantee its absence. To assess the reliability of these diagnostic tools, healthcare practitioners rely on two key statistical indicators: sensitivity and specificity.
Sensitivity is the...
729