X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
New Radioprotective Device that can be Used for Fluoroscopic Exam: Possibility to Contribute to Staff Exposure
Yoshiaki Morishima1,2, Koichi Chida3, Osamu Ito4
1Department of Radiology, Tohoku Medical and Pharmaceutical University Hospital, 1-12-1 Fukumuro, Miyagino-ku, Sendai, 983-8512, Japan. morishima@med.tohoku.ac.jp.
Abstract:
The videofluoroscopic swallowing study (VFSS) is a recognized standard diagnostic imaging technique that is used to investigate swallowing disorders and dysphagia. Patients were assessed in a seated posture on a chair or wheelchair. Using X-ray fluoroscopy, the state of patients' swallowing was checked by eating and drinking according to the physician's instructions. VFSS procedures are prolonged, and VFSS staff members are exposed to radiation. Therefore, we evaluated original lead shielding device (OLSD) that can be attached to the handrail of a table and placed vertically. The OLSD has a lead-equivalent thickness of 0.3 mmPb, weighs about 6 kg, and has the dimensions 50 cm × 50 cm × 8.0 mm. We used a human phantom and a radiation survey meter with and without protection from scattered radiation at the positions of the physician and medical staff at the height of 150 cm above the floor (i.e., the height of the eye's crystalline lens). After measuring the scattered radiation, we created radiation maps with and without the OLSD. The dose rate at the physician's position without and with the OLSD was 190 µSv/h and 92 µSv/h, respectively, and a dose reduction of 51.6% with the plate. Moreover, the radiation maps added clarity to the distribution of the scattered radiation. Such information should lead to greater awareness about exposures to physicians and other medical staff. Thus, the OLSD effectively provided protection from scattered radiation at the physician's position during fluoroscopy. It may contribute to the reduction of staff exposure for VFSS.
More Related Videos
10:46Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies for Cardiovascular System V: CT
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):