Related Experiment Video
Updated: Oct 3, 2025

Retinal and Choroidal Thickness Changes in Populations with Helicobacter pylori Infection by Swept-Source Optical Coherence Tomography
Published on: November 1, 2024
Does choroidal thickness change in advanced hemorrhoids patients?
Background:
This study was conducted to examine the choroidal thickness of patients with grade 4 hemorrhoids to see if vascular abnormalities in hemorrhoid patients may affect other `parts of the body.
Methods:
51 patients diagnosed with grade 4 hemorrhoids in the last two years and 49 healthy volunteers were included. Choroidal evaluation was done by measurements from various points of the choroid using a spectral domain Cirrus HD-OCT (Carl Zeiss Meditec Inc.) in enhanced-depth imaging mode. Choroidal thicknesses were compared between the two groups.
Results:
Nasal choroidal thickness, temporal choroidal thickness and mean choroidal thickness measurements were significantly higher in the hemoroid group (p<0.05), while subfoveal choroidal thickness did not differ significantly between the groups. Macular thickness was also significantly higher in the hemoroid group compared to the control group (p<0.05).
Conclusion:
There was an increase in choroidal thickness in patients with grade 4 hemorrhoids.
Key Words:
Choroidal thickness, Hemorrhoids, Macular thickness, Optical coherence tomography, Vascular pathologies.
More Related Videos
03:35Determining Gender-Based Differences in Retinal and Choroidal Thickness in Underweight Individuals via Swept-Source Optical Coherence Tomography
Published on: December 1, 2023
06:15Author Spotlight: Anterior HR-OCT as a Non-Invasive Tool for Characterizing Ocular Surface Squamous Neoplasia