Assessing the inter-rater and intra-rater reliability of the Physical Therapy Competence Assessment for Airway
Erin Miller1,2, Dina Brooks1,2,3,4,5, Kelly K O'Brien1,2,6
1Rehabilitation Sciences Institute, University of Toronto, Toronto, Ontario, Canada.
Background And Purpose:
The Physical Therapy Competence Assessment for Airway Suctioning (PT-CAAS) is a recently developed measure to assess the clinical competence of physiotherapists who perform airway suctioning with adults. The purpose of this study was to assess the inter-rater and intra-rater reliability of the PT-CAAS.
Methods:
Scoring rules were developed through expert consultation. Reliability was then assessed using nine videos of suctioning performed in a simulated learning environment. A repeated measures design was used, with two replicate sets of measurements made by each participant for all videos. Data were analyzed using a repeated measures model for the concurrent assessment of inter-rater and intra-rater reliability. Participants were physiotherapists with suctioning experience.
Results:
Twenty physiotherapists completed initial scoring and re-scoring for all nine videos; their data were included in the analysis. Intraclass correlation coefficients (ICCs) for inter-rater reliability ranged from 0.569 [lower one-sided 95% confidence interval (CI): 0.395; standard error of measurement (SEM): 0.963] for infection control to 0.759 (lower one-sided 95% CI: 0.612; SEM: 0.722) for post-suctioning assessment and care. The inter-rater ICC for overall performance was 0.752 (lower one-sided 95% CI: 0.602; SEM: 0.660). ICCs for intra-rater reliability ranged from 0.759 (lower one-sided 95% CI: 0.197; SEM 0.721) for infection control to 0.860 (lower one-sided 95% CI: 0.544; SEM: 0.550) for post-suctioning assessment and care. The intra-rater ICC for overall performance was 0.867 (lower one-sided 95% CI: 0.559; SEM: 0.483).
Discussion:
Evidence of moderate to good inter-rater and good intra-rater reliability was found; however, the results should be interpreted with caution given the wide CIs and relatively large SEMs. Improved assessor training and assessments of reliability using a larger sample size are recommended.
Related Concept Videos
Tracheostomy Suctioning II: Procedure
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...