Related Experiment Video
Updated: Oct 3, 2025

Avocado Sample Preparation Using the QuEChERS Method with Ammonium Formate for Pesticide Analysis
Published on: December 8, 2023
Determination of Highly Polar and Ionic Pesticides in Grape and Pomegranate Using Liquid Chromatography Tandem Mass
Raviraj Shinde1, Kaushik Banerjee1
1National Reference Laboratory, ICAR-National Research Centre for Grapes, P.O. Manjri Farm, Pune 412307, India.
Background:
Residues of polar pesticides cannot be determined by QuEChERS-based multiresidue extractions because of their non-amenability to reverse-phase chromatographic separation and poor recoveries. On the other hand, single-residue methods pose limitations because of the various requirements of sample preparation and LC-MS/MS conditions. A new multiresidue method is thus warranted for rapid and simultaneous analysis of polar pesticides.
Objective:
The study developed a multiresidue method for the simultaneous analysis of glyphosate and its metabolite (aminomethylphosphonic acid, AMPA), glufosinate and its metabolites (3-methylphosphinicopropionic acid and N-acetyl-glufosinate), ethephon, fosetyl-aluminum and its metabolite (phosphonic acid), and trimesium in grape and pomegranate by LC-MS/MS.
Method:
The homogenized samples (10 g) were extracted with acidified methanol (20 mL). An aliquot of the extract was diluted with acetonitrile (1 + 1) and measured by LC-MS/MS using a Torus DEA column. The performance of a hydrophilic interaction liquid chromatography (HILIC) column and an "anionic polar pesticides" (APP) column was also evaluated.
Results:
The method performance on the Torus DEA column was satisfactory for all compounds (recoveries = 77-104%, repeatability-RSD, <11%) at limit of quantification (LOQ) (0.01 mg/kg), and with higher levels in grape and pomegranate. The only exception was AMPA, which had an LOQ of 0.05 mg/kg. In the APP column, AMPA could be determined with an LOQ of 0.01 mg/kg. Trimesium, which had poor retention in Torus DEA, performed better in an XBridge HILIC column (retention time = 4.2 min, LOQ = 0.01 mg/kg). The inter-laboratory validation experiment yielded comparable results with high accuracy and precision.
Conclusions:
The method could screen the residues of all compounds on a Torus DEA column. For AMPA and trimesium, the APP and XBridge HILIC columns provided superior method performances. Since isotopically labeled internal standards were not required, the method appeared cost-effective. Considering its compliance with the SANTE/12682/2019 validation guidelines and EU-MRLs, the method can be recommended for regulatory testing purposes.
Highlights:
A high-throughput residue analysis method targeting nine polar and ionic compounds in grape and pomegranate involved a single multiresidue extraction, followed by direct analysis using LC-MS/MS. A satisfactory method performance was achieved through intra- and inter-laboratory validation. The method sensitivity met the EU-MRLs and the SANTE/12682/2019 analytical quality control criteria.
More Related Videos
11:17A Simple Fractionated Extraction Method for the Comprehensive Analysis of Metabolites, Lipids, and Proteins from a Single Sample
Published on: June 1, 2017
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...