Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
Coupling of chiral and achiral stationary phases in supercritical fluid chromatography: Evaluating and improving
Petra Riasová1, Pavel Jáč2, Miroslav Polášek2
1Vrije Universiteit Brussel (VUB), Department of Analytical Chemistry, Applied Chemometrics and Molecular Modelling, Faculty of Medicine and Pharmacy, Laarbeeklaan 103, B-1090 Brussels, Belgium; Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Akademika Heyrovského 1203, CZ-500 05 Hradec Králové, Czech Republic.
Abstract:
Isomers and stereoisomers are always challenging to separate. Column coupling may provide improved chromatographic selectivity, necessary for the separation of the compounds with similar chemical and structural properties. The relatively low viscosity of supercritical fluids, used as mobile phases allows for the coupling of several columns in series in supercritical fluid chromatography (SFC), without exceeding the pressure limits of the system. The aim of this study is to propose reliable prediction of the retention behaviour of analytes on a coupled column system, based on a limited number of initial analyses. The chiral compounds atenolol, ephedrine, propranolol, mianserin, labetalol and nadolol, besides the diastereomers quinine and quinidine, and the structural isomers of aminophenol and aminocresol were used as model analytes. The retention behaviour of the analytes was determined on the individual chiral columns Lux Cellulose-1, Lux Cellulose-2, Lux Cellulose-3, Lux Cellulose-4, Lux Amylose-2 and the achiral columns Luna NH2, Luna Silica, Synergi RP and FluoroSep RP. The mobile phase was composed of CO2 mixed with 20% (v/v) MeOH, which contained 0.1% (v/v) trifluoroacetic acid and 0.1% (v/v) isopropylamine. The retention factors of the analytes on coupled stationary phases were predicted, and subsequently compared to the experimentally obtained ones. Relative deviations of predicted and experimental retention factors were in range from 0.00% to 51.91%. Flow rate and back pressure of the screening conditions were adjusted to improve prediction precision on four column combinations, with varying success rates. The average relative deviations of retention factors were reduced to 2.84% - 6.59% by adjusting flow rate, and to 2.30% - 8.57% by adjusting back pressure. The most successful approach, flow rate adjustment, was then applied to select a column combination providing improved resolution of the structurally similar components of silymarin extract.
More Related Videos
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...