Related Experiment Video
Updated: Oct 3, 2025

Normothermic Ex Vivo Liver Machine Perfusion in Mouse
Published on: September 25, 2023
Improved Flow Dynamics of Extracorporeal Membrane Oxygenation via Design Modification of Dual-Lumen Cannulas
Marjan Azimi1,2, Sam Liao1,2, Ashkan Vatani1,2
1From the Department of Mechanical and Aerospace Engineering, Monash University, Clayton, Australia.
Abstract:
Veno-venous extracorporeal membrane oxygenation (VV-ECMO) supports patients with severe respiratory failure not responding to conventional treatments. Single-site jugular venous cannulation with dual-lumen cannulas (DLC) have several advantages over traditional single-lumen cannulas, however, bleeding and thrombosis are common, limiting their clinical utility. This study numerically investigated the effects of DLC side holes on blood flow dynamics since the maximum wall shear stress (WSS) occurs around the side holes. A DLC based on the Avalon Elite 27Fr model was implanted into an idealized 3D model of the vena cava and right atrium (RA). Eight DLCs were developed by changing the number, diameter, and spacing of side holes through an iterative design process. Physiologic flow at the inferior vena cava (IVC) and superior vena cava (SVC) were applied along with a partial ECMO support of 2 L/min. The SST k-ω turbulent model was solved for 6.4 seconds. WSS, washout, stagnation volume, and recirculation were compared. For all DLCs, no stasis region lasted more than one cardiac cycle and a complete washout was obtained in less than 4 seconds. Due to the IVC and SVC backflows, maximum WSS occurred around the DLC side holes at late systole and late diastole. A DLC with 16 and three side holes within the IVC and SVC, respectively, reduced the maximum WSS by up to 67% over the Avalon Elite 27Fr. Improved DLCs provided a more uniform WSS distribution with lower WSS around the side holes, potentially reducing the chance of thrombosis and bleeding.
More Related Videos
07:41Insertion, Maintenance, and Removal of the Percutaneous Dual Lumen Cannula Right Ventricular Assist Device
Published on: July 20, 2022
06:22Author Spotlight: Advancing Cardiovascular Research — Tailored Langendorff Perfusion Techniques for Improved Experimental Outcomes
Published on: June 14, 2024
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...