2% aqueous vs alcohol-based chlorhexidine for skin antisepsis in VLBW neonates undergoing peripheral venipuncture: a
Amish Jain1, Poorva Deshpande2, Eugene W Yoon3
1Department of Paediatrics, University of Toronto, Toronto, Canada. amish.jain@sinaihealth.ca.
Objective:
To compare 2% aqueous chlorhexidine gluconate (AQC) vs. 2% chlorhexidine gluconate in 70% isopropyl alcohol (ALC) for pre-venipuncture skin antisepsis in very-low-birth-weight neonates (VLBW, birth-weight <1500 grams).
Study Design:
Double-blind, non-inferiority trial randomized 199 VLBW neonates, age 2-28 days, to receive pre-venipuncture skin preparation using single application of swabstick impregnated with AQC (n = 99) or ALC (n = 100). Skin clearance rate (percentage post-cleansing skin swabs with <15 bacterial colony forming units) with a 10% non-inferiority margin for AQC was primary outcome. Absolute and relative CFU reduction and adverse skin reactions were compared.
Results:
AQC's clearance was non-inferior to ALC (91% vs. 88%; 95% CI -6.6%, +12.4%). Median (interquartile range) absolute [61 (16, 110) vs. 63 (18, 100); p = 0.65] and relative [100% (97%, 100%) vs. 100% (99.7%, 100%); p = 0.20] CFU reductions were similar. Neither group experienced any adverse reactions.
Conclusion:
AQC may provide non-inferior skin disinfection to ALC in VLBW neonates.
Clinical Trial Registration:
ClinicalTrials.gov NCT01270776.
Related Concept Videos
Hand hygiene
Hand washing...
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...
Local Anesthetics: Clinical Application as Surface, Infiltration, and Conduction Block Anesthesia
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...