Related Experiment Video
Updated: Oct 3, 2025

Isolation of Mouse Respiratory Epithelial Cells and Exposure to Experimental Cigarette Smoke at Air Liquid Interface
Published on: February 21, 2011
Measurement of particulate matter 2.5 in surgical smoke and its health hazards
Kae Okoshi1,2, Koya Hida3, Koichi Kinoshita4
1Department of Surgery, Japan Baptist Hospital, 47 Yamonomoto-cho, Kitashirakawa, Sakyo-ku, Kyoto, 606-8273, Japan. kae_md@kuhp.kyoto-u.ac.jp.
Purpose:
Surgical smoke is generated during the cauterization, coagulation, and incision of biological tissues by electrocautery, ultrasonic coagulation, incising devices, and lasers. Surgical smoke comprises water, water vapor, steam, and some particulate matter, including bacteria, viruses, cell fragments, and volatile organic compounds, which can pose health risks to the operating room personnel. In this study, we measured the concentration of particulate matter 2.5 (particles with a diameter of ≤ 2.5 μm) in surgical smoke.
Methods:
We used digital dust counters for real-time monitoring of particulate matter 2.5 generated intraoperatively in breast and gastrointestinal surgeries performed at our hospitals between 2019 and 2020.
Results:
Concentrations of particulate matter 2.5 were measured in surgical smoke generated when performing 14 different surgeries. Immediately after electrocautery, the concentration of particulate matter 2.5 increased to 2258 μg/m3 and then, when we stopped using the devices, it decreased rapidly to the initial levels. Interestingly, the concentrations increased after each intermittent electrocautery procedure. Higher concentrations of particulate matter 2.5 were observed during breast surgeries than during laparoscopic procedures.
Conclusion:
Surgical smoke poses potential health risks to operating room personnel by contaminating their breathing zone with high concentrations of particulate matter 2.5. A local exhaust ventilation system is needed to reduce exposure.