Related Experiment Video
Updated: Oct 3, 2025

Author Spotlight: Advancing Awake Nasotracheal Intubation with Flexible Video Rhino-Laryngoscopes
Published on: August 2, 2024
Frequency and Risk Factors for Difficult Intubation in Women Undergoing General Anesthesia for Cesarean Delivery: A
Sharon C Reale1, Melissa E Bauer2, Thomas T Klumpner3
1Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts.
Background:
Estimates for the incidence of difficult intubation in the obstetric population vary widely, although previous studies reporting rates of difficult intubation in obstetrics are older and limited by smaller samples. The goals of this study were to provide a contemporary estimate of the frequency of difficult and failed intubation in women undergoing general anesthesia for cesarean delivery and to elucidate risk factors for difficult intubation in women undergoing general anesthesia for cesarean delivery.
Methods:
This is a multicenter, retrospective cohort study utilizing the Multicenter Perioperative Outcomes Group database. The study population included women aged 15 to 44 yr undergoing general anesthesia for cesarean delivery between 2004 and 2019 at 1 of 45 medical centers. Coprimary outcomes included the frequencies of difficult and failed intubation. Difficult intubation was defined as Cormack-Lehane view of 3 or greater, three or more intubation attempts, rescue fiberoptic intubation, rescue supraglottic airway, or surgical airway. Failed intubation was defined as any attempt at intubation without successful endotracheal tube placement. The rates of difficult and failed intubation were assessed. Several patient demographic, anatomical, and obstetric factors were evaluated for potential associations with difficult intubation.
Results:
This study identified 14,748 cases of cesarean delivery performed under general anesthesia. There were 295 cases of difficult intubation, with a frequency of 1:49 (95% CI, 1:55 to 1:44; n = 14,531). There were 18 cases of failed intubation, with a frequency of 1:808 (95% CI, 1:1,276 to 1:511; n = 14,537). Factors with the highest point estimates for the odds of difficult intubation included increased body mass index, Mallampati score III or IV, small hyoid-to-mentum distance, limited jaw protrusion, limited mouth opening, and cervical spine limitations.
Conclusions:
In this large, multicenter, contemporary study of more than 14,000 general anesthetics for cesarean delivery, an overall risk of difficult intubation of 1:49 and a risk of failed intubation of 1:808 were observed. Most risk factors for difficult intubation were nonobstetric in nature. These data demonstrate that difficult intubation in obstetrics remains an ongoing concern.
More Related Videos
04:30Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine
Published on: August 25, 2022
05:39Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques