Related Experiment Video
Updated: Oct 3, 2025

Non-invasive 3D-Visualization with Sub-micron Resolution Using Synchrotron-X-ray-tomography
Published on: May 27, 2008
Exploring spectroscopic X-ray nano-imaging with Zernike phase contrast enhancement
1Pohang Accelerator Laboratory, Pohang University of Science and Technology, Jigokro 127, Pohang, Kyungbuk, 37637, Republic of Korea.
Abstract:
Spectroscopic full-field transmission X-ray microscopy (TXM-XANES), which offers electrochemical imaging with a spatial resolution of tens of nanometers, is an extensively used unique technique in battery research. However, absorption-based bright-field imaging has poor detection sensitivity for nanoscale applications. Here, to improve the sensitivity, we explored spectroscopic X-ray nano imaging with Zernike phase contrast (ZPC-XANES). A pinhole-type Zernike phase plate, which was optimized for high-contrast images with minimal artifacts, was used in this study. When the absorption is weak, the Zernike phase contrast improves the signal-to-noise ratio and the contrast of images at all energies, which induces the enhancement of the absorption edge step. We estimated that the absorption of the samples should be higher than 2.2% for reliable spectroscopic nano-imaging based on XANES spectroscopy analysis of a custom-made copper wedge sample. We also determined that there is a slight absorption peak shift and sharpening in a small absorption sample due to the inflection point of the refractive index at the absorption edge. Nevertheless, in the case of sub-micron sized cathode materials, we believe that better contrast and higher resolution spectroscopic images can be obtained using ZPC-XANES.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
X-ray Imaging
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Nuclear Overhauser Enhancement (NOE)
Super-resolution Fluorescence Microscopy

