Related Experiment Video
Updated: Oct 3, 2025

In vitro Assessment of Aortic Regurgitation Using Four-Dimensional Flow Magnetic Resonance Imaging
Published on: February 25, 2022
Two wrongs sometimes do make a right: errors in aortic valve stenosis assessment by same-day Doppler echocardiography
Hyungkyu Huh1, Jeesoo Lee2, Menhel Kinno3
1Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation, Daegu, South Korea.
Abstract:
This study aims to systematically verify if the simplified geometry and flow profile of the left ventricular outflow tract (LVOT) assumed in 2D echocardiography is appropriate while examining the utility of 4D flow MRI to assess valvular disease. This prospective study obtained same-day Doppler echocardiography and 4D flow MRI in 37 healthy volunteers (age: 51.9 ± 18.2, 20 females) and 7 aortic stenosis (AS) patients (age: 64.2 ± 9.6, 1 female). Two critical assumptions made in echocardiography for aortic valve area assessment were examined, i.e. the assumption of (1) a circular LVOT shape and (2) a flat velocity profile through the LVOT. 3D velocity and shape information obtained with 4D flow MRI was used as comparison. It was found that the LVOT area was lower (by 26.5% and 24.5%) and the velocity time integral (VTI) was higher (by 28.5% and 30.2%) with echo in the healthy and AS group, respectively. These competing errors largely cancelled out when examining individual and cohort averaged LVOT stroke volume. The LVOT area, VTI and stroke volume measured by echo and 4D flow MRI were 3.6 ± 0.7 vs. 4.9 ± 1.0 cm2 (p < 0.001), 21.2 ± 3.0 vs 15.2 ± 2.8 cm (p < 0.001), and 75.6 ± 15.6 vs 72.8 ± 14.1 ml (p = 0.3376), respectively. In the ensemble average of LVOT area and VTI, under- and over-estimation seem to compensate each other to result in a 'realistic' stroke volume. However, it is important to understand that this compensation may fail. 4D flow MRI provides a unique insight into this phenomenon.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
12:12Echocardiographic Approaches and Protocols for Comprehensive Phenotypic Characterization of Valvular Heart Disease in Mice
Published on: February 14, 2017
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Mitral Stenosis II: Clinical features and Diagnostic Tests