Related Experiment Video
Updated: Oct 2, 2025

Calvarial Model of Bone Augmentation in Rabbit for Assessment of Bone Growth and Neovascularization in Bone Substitution Materials
Published on: August 13, 2019
Randomized controlled clinical trial comparing guided bone regeneration of peri-implant defects with soft-type block
Goran I Benic1, Stefan P Bienz1, Young Woo Song2,3
1Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland.
Aim:
To test whether soft-type block bone substitute used for guided bone regeneration (GBR) of peri-implant defects leads to a different dimension of the augmented hard tissue than particulate bone substitute.
Materials And Methods:
In 40 patients, 40 two-piece dental implants were placed >2 months after tooth extraction. Following random allocation, 20 peri-implant bone dehiscences were grafted with a soft-type block made of synthetic biphasic calcium phosphate (BCP) + collagen and 20 bone dehiscences with particulate BCP. All the sites were covered with a collagen membrane stabilized with titanium pins. Immediately after wound closure and after 6 months, the horizontal dimension (HD) of the augmented hard tissue was measured at the level of implant shoulder using cone beam computed tomography. During re-entry at 6 months, the defect fill was clinically assessed.
Results:
At 6 months, the median HD measured 1.15 mm (mean: 1.31 mm) in the soft-block group and 0.93 mm (mean: 1.05 mm) in the particulate group (p = .6). At 6 months, 7.1% of contained defects and 61.9% of non-contained defects showed an incomplete vertical defect fill.
Conclusions:
Soft-type block of BCP + collagen used for GBR of peri-implant defects did not differ from particulate BCP regarding the dimension of the augmented hard tissue after 6 months of healing.