Related Experiment Video
Updated: Oct 2, 2025

O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
Genetic algorithm based artificial neural network and partial least squares regression methods to predict of
Shima Zandbaaf1, Mohammad Reza Khanmohammadi Khorrami1, Majid Ghahraman Afshar2
1Chemistry Department, Faculty of Science, Imam Khomeini International University, P.O. Box 3414896818, Qazvin, Iran.
Abstract:
The current study proposes a novel analytical method for calculating the breakdown voltage (BV) of transformer oil samples considered as a significant method to assess the safe operation of power industry. Transformer oil samples can be analyzed using the Attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy combined with multivariate calibration methods. The partial least squares regression (PLSR) back propagation-artificial neural network (BP-ANN) methods and a genetic algorithm (GA) for variable selection are used to predict and assess breakdown voltage in transformer oil samples from various Iranian transformer oils. As a result, the root mean square error (RMSE) and correlation coefficient for the training and test sets of oil samples are also calculated. In the GA-PLS-R method, the squared correlation coefficient (R2pred) and root mean square prediction error (RMSEP) are 0.9437 and 2.6835, respectively. GA-BP-ANN, on the other hand, had a lower RMSEP value (0.2874) and a higher R2pred function (0.9891). Considering the complexity of transformer oil samples, the performance of GA-BP-ANN has resulted in an efficient approach for predicting breakdown voltage; consequently, it can be effectively used as a new method for quantitative breakdown voltage analysis of samples to evaluate the health of transformer oil. .
More Related Videos
08:17Chemical Analysis of Water-accommodated Fractions of Crude Oil Spills Using TIMS-FT-ICR MS
Published on: March 3, 2017
10:50Detection and Quantification of Plasmodium falciparum in Aqueous Red Blood Cells by Attenuated Total Reflection Infrared Spectroscopy and Multivariate Data Analysis
Published on: November 2, 2018
Related Concept Videos
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Atomic Fluorescence Spectroscopy
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Transformers with Off-Nominal Turns Ratios
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Power System Three-Phase Short Circuits