Related Experiment Video
Updated: Oct 2, 2025

Visualization and Quantification of the Cell-free Layer in Arterioles of the Rat Cremaster Muscle
Published on: October 19, 2016
Dependence of cell-free-layer width on rheological parameters: Combining empirical data on flow separation at
Jakub Köry1, Philip K Maini1, Joe M Pitt-Francis2
1Mathematical Institute, University of Oxford, Oxford OX2 6GG, United Kingdom.
Abstract:
When blood flows through vessel networks, red blood cells (RBCs) are typically concentrated close to the vessel center line, creating a lubrication layer near the vessel wall. As RBCs bind oxygen, the width of this cell-free layer (CFL) impacts not only the blood rheology inside the vasculature, but also oxygen delivery to the tissues they perfuse and, hence, their function. Existing attempts to relate the width of the CFL to the rheological properties of the blood and the geometrical properties of the vessel are based on an analysis of the forces acting on RBCs suspended in the blood. However, the complexity of interactions in the blood makes this a challenging task. Here, we propose an alternative, two-step approach to derive such a functional relationship. First, we extend widely accepted empirical fits describing the minimum flow fraction needed for RBCs to enter a daughter vessel downstream of a microvascular bifurcation so that it depends not only on the diameter and discharge haematocrit of the parent vessel, but also on its average shear rate. Second, we propose a simple geometrical model for the minimum flow fraction based on the cross-sectional blood flow profile within the parent vessel upstream of the bifurcation-considering uniform, parabolic, and blunt velocity profiles-and derive the leading-order approximation to this model for small CFL widths. By equating the functional relationships obtained using these two approaches, we derive expressions relating the CFL width to the vessel diameter, discharge haematocrit, and mean shear rate. The resulting expressions are in good agreement with available in vivo data and represent a promising basis for future research.
More Related Videos
11:14A Microfluidic System with Surface Patterning for Investigating Cavitation Bubble(s)–Cell Interaction and the Resultant Bioeffects at the Single-cell Level
Published on: January 10, 2017
12:43Parallel-plate Flow Chamber and Continuous Flow Circuit to Evaluate Endothelial Progenitor Cells under Laminar Flow Shear Stress
Published on: January 17, 2012