Combination of CT/MRI LI-RADS with CEUS can improve the diagnostic performance for HCCs
Yan Zhou1, Jianmin Ding2, Zhengyi Qin2
1School of medicine, Nankai University, Tianjin 300071, China; Department of Ultrasound, Tianjin Third Central Hospital, Tianjin 300170, China; Tianjin Institute of Hepatobiliary Disease, Tianjin Key Laboratory of Extracorporeal Life Support for Critical Diseases, Artificial Cell Engineering Technology Research Center, Tianjin Third Central Hospital, Tianjin 300170, China.
Background & Aims:
To compare the classifications for focal liver lesions smaller than 3 cm by the CEUS and CT/MRI LI-RADS and explore the discrepancy between the two classifications strategies.
Methods:
Focal liver lesions with a size smaller than 3 cm undergoing CEUS and CT/MRI (MR required on a 3.0 T magnet) within 1 month were enrolled. Each nodule was categorized according to the CEUS LI-RADS v2017 (usLI-RADS) and CT/MRI LI-RADS v2018. Intermodality agreement between the usLI-RADS and LI-RADS for CT/MRI was assessed. The reasons for inconsistent classifications by the CEUS and CT/MRI LI-RADS were clarified.
Results:
A total of 213 lesions were included. The positive predictive value (PPV) for HCCs of LR-3, 4 and 5 were 57.1% (95% CI: 32.6-78.6), 75.0% (95% CI: 62.3-84.5) and 94.2% (95% CI: 88.9-97.0) for CT/MRI and 37.5% (95% CI: 18.5-61.4), 56.0% (95% CI: 37.1-73.3) and 97.9% (95% CI: 94.1-99.3) for CEUS, respectively. CECT/MRI and CEUS LI-RADS had a poor agreement in classification with a kappa value of 0.254 (P < 0.001). 84 lesions (39.4%) were classified inconsistently in CT/MRI and CEUS LI-RADS. 40 lesions classified as LR-3 or LR-4 by CT/MRI were upgraded by CEUS. 21 lesions classified as LR-4 or LR-5 by CT/MRI were downgraded by CEUS. We reclassified the lesion in CT/MRI LR-3 and LR-4 by CEUS. The PPVs for HCCs in reclassified LR-3, LR-4 and LR-5 were 27.3% (95% CI: 9.7-56.6), 41.7% (95% CI: 26.2-69.0) and 94.2% (95% CI: 89.3-97.0), respectively, which decreased the incidences of HCCs in CT/MRI LR-3 and LR-4.
Conclusion:
Lesions in CT/MRI LR-3 and 4 have a higher probability of being HCCs than those in usLR-3 and 4, respectively. Reclassification of lesions in CT/MRI LR-3 and 4 using CEUS can help the corresponding HCCs get a definite diagnosis.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System IV: CMRI