Related Experiment Video
Updated: Oct 2, 2025

Application of Biochip Microfluidic Technology to Detect Serum Allergen-specific Immunoglobulin E sIgE
Published on: April 21, 2019
Specific IgE and IgG4 Profiles of House Dust Mite Components in Allergen-Specific Immunotherapy
Lin Yang1, Yaqi Yang1, Qingxiu Xu1
1Department of Allergy, Tongji Hospital, Tongji Medical College of Huazhong University of Science and Technology, Wuhan, China.
Background:
Allergen immunotherapy (AIT) can induce immune tolerance to allergens by activating multiple mechanisms, including promoting IgG4 synthesis and blunting IgE production. However, the longitudinal data of sIgE and sIgG4 to allergen components during AIT are limited.
Objective:
We sought to investigate the persistence and evolution of sIgE and sIgG4 against house dust mite (HDM) components during AIT and explore their correlation with clinical responses.
Methods:
Sixty allergic rhinitis (AR) with/without asthma patients receiving AIT for HDM were enrolled in AIT group. Thirty AR patients without receiving AIT served as control group. Blood samples were collected for sIgE, sIgG4 to HDM components (Derp 1, Derf 1, Derp 2, Derf 2, Derp 7, Derp 10, Derp 21 and Derp 23) assay at baseline, Month 6 and Month 18 of AIT. Combined symptom and medication scores (CSMS) were obtained accordingly.
Results:
In the AIT group, sIgG4 to the HDM components of Derp 1, Derf 1, Derp 2 and Derf 2, Derp 21 significantly increased at Month 18 compared to the baseline (36.2 UA/mL vs 158.8 UA/mL, 46.4 UA/mL vs 94.6 UA/mL, 80.5 UA/mL vs 152.3 UA/mL, 78.3 UA/mL vs 205.1 UA/mL, 42.3 UA/mL vs 59.3 UA/mL, all p<0.05), sIgE to HDM components didn't see differences at baseline and at Month 18 (all p>0.05).The numbers of positive HDM component sIgE and sIgG4 increased from 4.5 to 5 and 0 to 1.5 respectively (both p<0.05). However, the changes of sIgE, sIgG4, sIgE/sIgG4 ratio and the numbers of positive HDM components had no correlations with the improvement of CSMS after AIT (all ρ<0.3). For the control group, the sIgE and sIgG4 did not change significantly during the observational period (all p>0.05).
Conclusion:
AIT can induce the production of sIgG4 to HDM components. However, the increased sIgG4 levels of HDM component do not correlate with the corresponding sIgE levels at baseline or with AIT response. sIgG4 to HDM components do not qualify as a biomarker to evaluate the efficacy of AIT.
Related Concept Videos
Allergic Reactions
Hypersensitivities
Types of Hypersensitivities
Hypersensitivity reactions are categorized into four types: Type 1, Type 2, Type 3, and Type 4. Each type has a distinct mechanism...
Antiasthma Drugs: Mast Cell Stabilizers and Anti-IgE Drugs
Mast cell stabilizers, such as cromolyn (also known as sodium cromoglycate) and nedocromil (Tilade), are effective drugs in asthma management. These stabilizers hinder histamine release by skillfully obstructing the activation of mast cells and other cellular entities. Notably, they navigate this task without...
Antibody Structure
Antibodies, also known as immunoglobulins (Ig), are essential players of the adaptive immune system. These antigen-binding proteins are produced by B cells and make up 20 percent of the total blood plasma by weight. In mammals, antibodies fall into five different classes, which each elicits a different biological response upon antigen binding.
The Y-Shaped Structure of Antibodies Consists of Four Polypeptide Chains
Antibodies consist of four polypeptide chains: two identical heavy...
Allergic Drug Reactions
Asthma-IV: Diagnostic and Management
Clinical Assessment for Asthma:
This is the first step in diagnosing and managing asthma. It includes: