Feasibility Study of Dose Modulation for Reducing Radiation Dose with Arms-Down Patient Position in Abdominal
Jina Shim1, Yong Eun Chung2, Hyun-Woo Jeong3
1Department of Diagnostic Radiology, Severance Hospital, 50-1, Yonsei-ro, Seodaemun-gu, Seoul 03722, Korea.
Abstract:
This study was carried out to demonstrate whether the radiation dose for patients in arms-down position can be reduced without affecting the diagnosis on abdominal computed tomography (CT). The patients were divided into two groups: group A, which included patients with arms-down position using dose modulation on, and group B, which included patients with arms-down position using dose modulation turned off. Quantitative evaluation was compared using Hounsfield units, standard deviation, and signal-to-noise ratio of the four regions. The qualitative evaluation was assessed for overall image quality, subjective image noise, and beam hardening artifacts. Dose evaluation for CT dose index (CTDI) and dose length product (DLP) was compared by comparing the CT images with dose modulation turned on and off. In the quantitative and qualitative evaluation, there was no statistically significant difference between groups A and B (p > 0.05). In the dose evaluation, the CT images with dose modulation turned off had significantly lower CTDI and DLP than the CT images with dose modulation turned on (p < 0.05). Our results suggest that, for the GE Revolution EVO CT scanner, turning off dose modulation and increasing the tube voltage can reduce the radiation dose for patients with the arms-down position without affecting the diagnosis. This study did not consider the change of tube potential according to the use of dose modulation, and we plan to conduct additional research in the future.
More Related Videos
11:38Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET