Related Experiment Video
Updated: Oct 2, 2025

Experimental Endocarditis Model of Methicillin Resistant Staphylococcus aureus MRSA in Rat
Published on: June 4, 2012
Enterococcus durans Cardiac Implantable Electronic Device Lead Infection and Review of Enterococcus durans
Milan Radovanovic1,2, Djordje Jevtic3, Michel K Barsoum1,4
1Mayo Clinic Alix School of Medicine, Rochester, MN 55905, USA.
Abstract:
Introduction: Cardiac implantable electronic device (CIED) infections present a growing problem in medicine due to a significant increase in the number of implanted devices and the age of the recipient population. Enterococcus spp. are Gram-positive, facultative anaerobic, lactic acid bacteria; they are relatively common pathogens in humans, but uncommon as the cause of CIED lead infections. Only eight cases of Enterococcus durans endocarditis have been reported in the literature thus far; however, there are no reported cases of Enterococcus durans CIED lead infection. Case presentation: A 58-year-old gentleman with a previously implanted St. Jude Medical single-chamber implantable cardioverter-defibrillator (ICD) due to tachy/brady arrhythmias presented with nonspecific constitutional symptoms (i.e., low-grade fevers, chills, fatigue), and was found to have innumerable bilateral pulmonary nodules via computed tomography angiography of the chest. Many of these pulmonary nodules were cavitated and highly concerning for septic pulmonary emboli and infarcts. Within 24 h from presentation, blood cultures in all four culture bottles grew ampicillin- and vancomycin-susceptible Enterococcus durans. Transthoracic echocardiogram confirmed vegetations on the ICD lead in the right ventricle. The patient underwent laser extraction of the ICD lead with generator removal and recovered completely after a 6-week intravenous antibiotic course. Conclusion: To our knowledge, this is the first report of CIED lead infection caused by Enterococcus durans. In this case, management with antibiotics along with ICD lead extraction led to complete recovery. Clinicians should be aware of this rare but potentially devastating infection in patients with native and artificial valves, but also in those with CIEDs.
More Related Videos
07:50An In Vitro Model of a Parallel-Plate Perfusion System to Study Bacterial Adherence to Graft Tissues
Published on: January 7, 2019
10:04A Zebrafish Embryo Model for In Vivo Visualization and Intravital Analysis of Biomaterial-associated Staphylococcus aureus Infection
Published on: January 7, 2019
Related Concept Videos
Endocarditis I: Introduction
Endocarditis III: Medical Management
Endocarditis II: Clinical Features of Infective Endocarditis
Endocarditis IV: Nursing Management
Healthcare Associated Infections I: Iatrogenic, Exogenic and Endogenic
HAIs significantly increase the cost of health care. Extended stays in healthcare institutions, increased disability, increased costs of medications, including specialized antibiotics, and prolonged recovery times add to the patient's expenses and the healthcare institution and funding bodies.
Cardiomyopathy V: Interprofessional Care