Objectives:
This study sought to investigate the temporal association between changes in physiologic heart failure (HF) sensors, atrial fibrillation (AF) progression, and clinical HF in patients with cardiac resynchronization therapy implantable defibrillators (CRT-D) designed to monitor AF and HF daily.
Background:
AF is a common comorbidity in HF; however, it is unclear if HF triggers AF, or vice-versa. Current implantable cardiac devices have sensors capable of quantifying HF status, which permits a greater understanding of the impact of AF on HF status and may help guide treatment.
Methods:
The MultiSENSE (Multisensor Chronic Evaluation in Ambulatory Heart Failure Patients) study collected multiple sensor data indicative of HF status in patients with CRT-D followed for up to 12 months. Patients were grouped according to their longest daily AF burden: 1) at least 24 hours of AF (HIGH AF); 2) between 6 minutes and 24 hours (MID AF); and 3) <6 minutes (NO AF). Sensor data were aligned to the first qualifying AF event or a randomly selected day for patients in the NO AF group.
Results:
Among 869 patients with daily AF data available, 98 patients had HIGH AF, 141 patients MID AF, and 630 patients NO AF. At baseline, history of AF, N-terminal pro hormone B-type natriuretic peptide and device-measured S3 were associated with development of AF. HeartLogic index increased before AF onset (Δ HeartLogic = 9.83 ± 2.49; P < 0.001). Multivariable time-dependent Cox regression showed an increased risk for HF events following a 24-hour AF episode compared with no 24-hour AF (hazard ratio: 1.96; 95% confidence interval: 1.03-3.74).
Conclusions:
Device-measured HF indicators worsened before AF onset, whereas clinical HF deterioration only became apparent after AF occurred. Thus, the sensitivity of methods to ascertain AF and HF status appear to influence the direction of perceived causality. (Multisensor Chronic Evaluation in Ambulatory Heart Failure Patients [MultiSENSE]; NCT01128166).
More Related Videos
28:13Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
Published on: February 26, 2013
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Related Concept Videos
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Dysrhythmias V: Evaluating Dysrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Cardiomyopathy II: Dilated Cardiomyopathy
Heart Failure IV: Classification and Diagnostic Evaluation