Symmetric-Key-Based Authentication among the Nodes in a Wireless Sensor and Actuator Network

Thibaut Vandervelden1, Ruben De Smet2, Kris Steenhaut2

  • 1Department of Engineering Sciences and Technology (INDI), Vrije Universiteit Brussel (VUB), 1050 Brussels, Belgium.

Summary

This study introduces a secure symmetric-key mechanism for industrial automation networks, ensuring data authenticity and nonrepudiation. The novel approach enhances security even if some nodes are compromised, unlike traditional systems.

Related Concept Videos

Network Function of a Circuit01:25

Network Function of a Circuit

Frequency response analysis in electrical circuits provides vital insights into a circuit's behavior as the frequency of the input signal changes. The transfer function, a mathematical tool, is instrumental in understanding this behavior. It defines the relationship between phasor output and input and comes in four types: voltage gain, current gain, transfer impedance, and transfer admittance. The critical components of the transfer function are the poles and zeros.
415
Pilot and Numeric Relaying01:21

Pilot and Numeric Relaying

Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
151
Nodal Analysis01:10

Nodal Analysis

Nodal analysis is a fundamental method in electrical engineering used to simplify the process of circuit analysis. This method revolves around the concept of using node voltages as the primary variables for circuit analysis. The objective is to determine the voltage at each node in a circuit, which can then be used to find other quantities of interest, such as currents through specific components.
Consider, for instance, a simple circuit composed of three nodes and three resistors, as shown in...
1.2K
Radial System Protection01:23

Radial System Protection

Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
158
Contact-dependent Signaling01:19

Contact-dependent Signaling

Contact-dependent signaling, as the name suggests, requires that communicating cells be in direct contact with each other. This is achieved either through receptor-ligand interactions or by specialized cytoplasmic channels that allow the flow of small molecules between cells. In animal cells, channels called gap junctions facilitate contact-dependent signaling in certain tissues, whereas, plasmodesmata perform a similar function in plants.
Gap Junctions
In animal cells, gap junctions are formed...
45.2K
Signal and System01:26

Signal and System

A signal x(t) is a set of data or a time function representing a variable of interest. Signals typically convey information about a phenomenon, such as atmospheric temperature, humidity, human voice, television images, a dog's bark, or birdsongs. More generally, a signal can be a function of more than one independent variable. For instance, images depend on horizontal and vertical positions and can be regarded as two-dimensional signals. However, this text will focus on one-dimensional...
1.2K