Related Experiment Video
Updated: Oct 2, 2025

Subsurface Defect Localization by Structured Heating Using Laser Projected Photothermal Thermography
Published on: May 15, 2017
Application of Thermography and Adversarial Reconstruction Anomaly Detection in Power Cast-Resin Transformer
Kuo-Hao Fanchiang1, Cheng-Chien Kuo1
1Department of Electrical Engineering, National Taiwan University of Science and Technology, Taipei 106335, Taiwan.
Abstract:
Dry-type power transformers play a critical role in the power system. Detecting various overheating faults in the running state of the power transformer is necessary to avoid the collapse of the power system. In this paper, we propose a novel deep variational autoencoder-based anomaly detection method to recognize the overheating position in the operation of the dry-type transformer. Firstly, the thermal images of the transformer are acquired by the thermal camera and collected for training and testing datasets. Next, the variational autoencoder-based generative adversarial networks are trained to generate the normal images with different running conditions from heavy to light loading. Through the pixel-wise cosine difference between original and reconstructed images, the residual images with faulty features are obtained. Finally, we evaluate the trained model and anomaly detection method on normal and abnormal testing images to demonstrate the effeteness and performance of the proposed work. The results show that our method effectively improves the anomaly accuracy, AUROC, F1-scores and average precision, which is more effective than other anomaly detection methods. The proposed method is simple, lightweight and has less storage size. It reveals great advantages for practical applications.
More Related Videos
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
07:03In Situ Surface Temperature Measurement in a Conveyor Belt Furnace via Inline Infrared Thermography
Published on: May 30, 2020
Related Concept Videos
Power System Three-Phase Short Circuits
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
Three-Winding Transformers
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
Instrument Transformers
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...