Solar disinfection - An appropriate water treatment method to inactivate faecal bacteria in cold climates
Anni Juvakoski1, Gaurav Singhal2, Manuel A Manzano3
1Department of Built Environment, School of Engineering, Aalto University, PO Box 15200, FI-00076 Aalto, Finland; Department of Environmental Technologies, INMAR-Marine Research Institute, Faculty of Marine and Environmental Sciences, University of Cádiz, Poligono Rio San Pedro s/n, Puerto Real, 11510 Cádiz, Spain.
Abstract:
Solar disinfection (SODIS) is an inexpensive drinking water treatment method applied in tropical and sub-tropical low-income countries. However, it has been unclear whether it functions adequately also in colder climates. To investigate this issue, SODIS experiments were performed in the humid continental climate of Finland by exposing faecally contaminated drinking water to natural solar radiation at different water temperatures (8-23 °C) and UV intensities (12-19 W/m2) in polyethylene (PE) bags. To establish an adequate benchmark, SODIS experiments with the same experimental design were additionally conducted in the Mediterranean climate of Spain in typical conditions of SODIS application (~39 °C and 42 W/m2). Out of all experiments, the highest coliform and enterococci inactivation efficiencies in terms of lowest required doses for 4-log disinfection (25 Wh/m2 and 60 Wh/m2, respectively) were obtained in humid continental climate at the lowest studied mean water temperature (8-11 °C). Despite the low mean UV irradiance (~19 Wh/m2), 4-log disinfection of coliforms and enterococci were also reached fast in these conditions (1 h 27 min and 3 h 18 min, respectively). Overall, the doses required for disinfection increased as the water temperatures and UV intensities of the experiments rose. Disinfection of 4-logs (> 99.99%) of both bacteria was reached in all SODIS experiments within 6 h, suggesting SODIS could be a sufficient household water treatment method also in colder climates, unlike previously thought. The effects of different water temperatures on bacterial inactivation were also tested in the absence of sunlight. Together the obtained results indicate that while water temperatures below or close to the optima of coliforms and enterococci (~10 °C) alone do not cause inactivation, these temperatures may enhance SODIS performance. This phenomenon is attributed to slower bacterial metabolism and hence slower photorepair induced by the low water temperature.
More Related Videos
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Physical Methods for Controlling Microbial Growth: Temperature
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of reducing fever
Pharmacological Methods of Reducing Fever:
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...


