Assessing Fluid Intolerance with Doppler Ultrasonography: A Physiological Framework
Related Experiment Video
Updated: Oct 2, 2025

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
1Health Sciences North Research Institute, 56 Walford Rd., Sudbury, ON P3E 2H2, Canada.
Abstract:
Ultrasonography is becoming the favored hemodynamic monitoring utensil of emergentologists, anesthesiologists and intensivists. While the roles of ultrasound grow and evolve, many clinical applications of ultrasound stem from qualitative, image-based protocols, especially for diagnosing and managing circulatory failure. Often, these algorithms imply or suggest treatment. For example, intravenous fluids are opted for or against based upon ultrasonographic signs of preload and estimation of the left ventricular ejection fraction. Though appealing, image-based algorithms skirt some foundational tenets of cardiac physiology; namely, (1) the relationship between cardiac filling and stroke volume varies considerably in the critically ill, (2) the correlation between cardiac filling and total vascular volume is poor and (3) the ejection fraction is not purely an appraisal of cardiac function but rather a measure of coupling between the ventricle and the arterial load. Therefore, management decisions could be enhanced by quantitative approaches, enabled by Doppler ultrasonography. Both fluid 'responsiveness' and 'tolerance' are evaluated by Doppler ultrasound, but the physiological relationship between these constructs is nebulous. Accordingly, it is argued that the link between them is founded upon the Frank-Starling-Sarnoff relationship and that this framework helps direct future ultrasound protocols, explains seemingly discordant findings and steers new routes of enquiry.
More Related Videos
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies II: Ultrasonography
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Urodynamic Studies: Uroflowmetry