Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Capillary Electrophoresis: Instrumentation01:20

Capillary Electrophoresis: Instrumentation

417
Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
417
Capillary Electrophoresis: Applications01:30

Capillary Electrophoresis: Applications

574
Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
574

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Association of bilirubin reduction rate after percutaneous transhepatic cholangiographic drainage with major complications in hilar cholangiocarcinoma.

BMC gastroenterology·2026
Same author

Correction: Efficacy and safety of BCMA-or GPRC5D-directed CD3 bispecific antibodies in relapsed/refractory multiple myeloma: a systematic review and meta-analysis of prospective clinical trials and real-world studies.

Frontiers in immunology·2026
Same author

Deciphering the tubulin code: roles and mechanisms of microtubule post-translational modifications in gastrointestinal tumors: a narrative review.

Journal of gastrointestinal oncology·2026
Same author

[Mechanism of Bushen Yijing Formula in improving cognitive function in Alzheimer<b>'</b>s disease model mice].

Zhejiang da xue xue bao. Yi xue ban = Journal of Zhejiang University. Medical sciences·2026
Same author

[Bushen Yijing formula attenuates amyloid β-protein deposition and oxidative damage in <i>Caenorhabditis elegans</i>].

Zhejiang da xue xue bao. Yi xue ban = Journal of Zhejiang University. Medical sciences·2026
Same author

Redox-senescence function of PON1 in hepatocellular carcinoma and its non-invasive assessment using super-resolution radiomics: a multi-center study.

Journal of translational medicine·2026

Related Experiment Video

Updated: Oct 2, 2025

Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow
09:45

Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow

Published on: February 4, 2011

27.7K

Conductivity-difference-enhanced DC dielectrophoretic particle separation in a microfluidic chip.

Deyu Li1, Weicheng Yu1, Teng Zhou2

  • 1Department of Marine Engineering, Dalian Maritime University, Dalian, 116026, China. yongxin@dlmu.edu.cn.

The Analyst
|February 28, 2022
PubMed
Summary

This study introduces a novel method to boost dielectrophoretic (DEP) force for particle separation in microfluidic chips. By utilizing conductivity differences in electrolyte solutions, enhanced DEP forces are achieved without higher voltages or complex designs.

More Related Videos

Microfluidic Device for the Separation of Non-Metastatic MCF-7 and Non-Tumor MCF-10A Breast Cancer Cells Using AC Dielectrophoresis
08:33

Microfluidic Device for the Separation of Non-Metastatic MCF-7 and Non-Tumor MCF-10A Breast Cancer Cells Using AC Dielectrophoresis

Published on: August 11, 2022

2.6K
Label-free Isolation and Enrichment of Cells Through Contactless Dielectrophoresis
10:38

Label-free Isolation and Enrichment of Cells Through Contactless Dielectrophoresis

Published on: September 3, 2013

16.2K

Related Experiment Videos

Last Updated: Oct 2, 2025

Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow
09:45

Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow

Published on: February 4, 2011

27.7K
Microfluidic Device for the Separation of Non-Metastatic MCF-7 and Non-Tumor MCF-10A Breast Cancer Cells Using AC Dielectrophoresis
08:33

Microfluidic Device for the Separation of Non-Metastatic MCF-7 and Non-Tumor MCF-10A Breast Cancer Cells Using AC Dielectrophoresis

Published on: August 11, 2022

2.6K
Label-free Isolation and Enrichment of Cells Through Contactless Dielectrophoresis
10:38

Label-free Isolation and Enrichment of Cells Through Contactless Dielectrophoresis

Published on: September 3, 2013

16.2K

Area of Science:

  • Microfluidics
  • Biophysics
  • Electrokinetics

Background:

  • Dielectrophoresis (DEP) is a key technique for manipulating and separating microparticles.
  • Enhancing DEP force is crucial for improving the efficiency of microfluidic particle separation.
  • Current methods often require higher voltages or intricate microchannel designs.

Purpose of the Study:

  • To present a simple, effective method for increasing dielectrophoretic force in microfluidic particle separation.
  • To investigate the relationship between conductivity ratio and DEP force.
  • To demonstrate a practical approach for enhanced particle separation.

Main Methods:

  • A conductivity-difference-based method using two immiscible electrolyte solutions.
  • Application of direct-current (DC) voltage across the liquid-liquid interface.
  • Theoretical analysis using equivalent circuit theory and numerical simulations.
  • Experimental verification of predicted outcomes.

Main Results:

  • An enhanced electric field gradient is generated at the liquid-liquid interface.
  • The dielectrophoretic (DEP) force, indicated by particle separation distance, increases as the conductivity ratio decreases.
  • Numerical simulations confirm that separation distance is influenced by electric field magnitude and orifice width.
  • The method was numerically predicted and experimentally verified.

Conclusions:

  • The conductivity-difference method effectively increases DEP force for particle separation.
  • This approach offers advantages by avoiding higher DC voltages or smaller orifices.
  • The findings provide a simple yet powerful tool for microfluidic particle manipulation.