Inactivation of Pathogens via Visible-Light Photolysis of Riboflavin-5′-Phosphate
Published on: April 6, 2022
SARS-CoV-2 variants inactivation of plasma units using a riboflavin and ultraviolet light-based photochemical
Alessandro Ferrari1, Irene Cassaniti1, Josè Camilla Sammartino1
1Molecular Virology Unit, Microbiology and Virology Department, IRCCS Policlinico San Matteo, Pavia, 27100, Italy.
Background:
Test the ability of Mirasol Pathogen Reduction Technology (PRT, Terumo BCT, Lakewood Co, USA) treatment with riboflavin and ultraviolet light (R + UV) in reducing SARS-CoV-2 infectivity while maintaining blood product quality.
Material And Methods:
SARS-CoV-2 strains were isolated and titrated to prepare cell free virus for plasma units infection. The units were then under treatment with Mirasol PRT. The infectious titers were determined before and after treatment with an in house microtitration assay on Vero E6 cells. Thirty-six plasma pool bags underwent PRT treatment.
Results:
In all the experiments, the measured titer following riboflavin and UV treatment was below the limit of detection of microtitration assay for all the different SARS-CoV-2 strains. Despite the high copies number detected by RT-PCR for each viral strain after treatment, viruses were completely inactivated and not able to infect VERO E6 cells.
Conclusion:
Riboflavin and UV light treatment effectively reduced the virus titers of human plasma to the limit of detection in tissue culture, regardless of the strain. These data suggest that pathogen reduction in blood products highlight the safety of CP therapy procedures for critically ill COVID-19 patients, while maintaining blood product quality.
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Biological Methods for Microbial Control
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Chemical Agents for Microbial Control