A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
Published on: October 17, 2017
Introduction of a Novel, Continuous, Noninvasive Estimation of Intracranial Pressure and Cerebral Perfusion Pressure
Ying Jiang1, Qing-Song Xie2, Xiao-Jun Wu3
1Department of Neurosurgery, Shanghai Chang Zheng Hospital, Shanghai, PR China.
Objective:
Hydrocephalus is a common but potentially life-threatening condition. However, valve malfunction makes further diagnosis difficult. Thus, we tried to develop a noninvasive method to detect the hydrocephalus intracranial pressure (ICP) during routine follow-up.
Methods:
In group I, the patient was recruited because a spinal tap test was necessary for either disease diagnosis or treatment. In group II, patients were diagnosed with high ICP hydrocephalus and received shunt surgery. The tympanic membrane temperatures (TMTs) were recorded and plotted against the spinal tap pressure (STP) and shunt valve pressures.
Results:
All patients in group I showed an above-normal STP (from 180 to 400 mm H2O). The STP presents with an inverted U-shaped curve when it is plotted against TMT (R2 = 0.9). When the STP was 286.1 mm H2O, the TMT approached its peak value, which was 38.61°C (101.5°F). However, when ICP was in the normal range (50-200 mm H2O), the TMT correlated with ICP in a linear regression model (R2 = 0.69; P < 0.001). In addition, the cerebral perfusion pressure (CPP) was calculated and plotted against TMT. The TMT-CPP was also shown as a parabola (R2 = 0.74). Based on the TMT-ICP algorithm, we invented a noninvasive ICP monitor system, which performs in a manner comparable to the Codman ICP Transducer (R2 = 0.9; P < 0.01).
Conclusions:
Both Y-Jiang TMT-ICP and TMT-CPP algorithms are useful to monitor the shunt outcomes and identify potential shunt failure. More importantly, these algorithms open the possibility for the rational acquisition of ICP and CPP noninvasively.
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...