Related Experiment Video
Updated: Oct 2, 2025

Anogenital Distance and Perineal Measurements of the Pelvic Organ Prolapse POP Quantification System
Published on: September 20, 2018
Correlation between pelvic floor ultrasound parameters and vaginal pressures in nulliparous women: a subanalysis of
Jonia Alshiek1,2, Qi Wei2, S Abbas Shobeiri3,4
1Department of Obstetrics & Gynecology, INOVA Women's Hospital, 3300 Gallows Road, Second floor South tower, Falls Church, VA, 22042-3307, USA.
Introduction And Hypothesis:
Pelvic floor ultrasound is used as a validated technique for measuring levator ani dimensions. Vaginal manometry has been used in the past as a method to assess levator ani muscle (LAM) strength. Whether the combination of both methods can contribute to our understanding of pelvic floor pathophysiology has not yet been described. We hypothesized that as female pelvic floor muscular hiatus increases, the vaginal pressure and strength decrease.
Methods:
We recruited 20 asymptomatic nulliparous women ages 18-85 years. Minimal levator hiatus (MLH) area, anteroposterior/left-right (AP/LR) diameter ratio, the distance between levator plate and the pubic symphysis (LP-PS) while at rest and squeeze were measured using endovaginal ultrasound (US). Vaginal pressure at rest, squeeze (Kegel) and Valsalva were measured using 3D manometry. Logistic and linear regression analysis was performed to assess correlations.
Results:
MLH area was negatively correlated with the sum of all the squeeze pressures produced on the four walls of the vagina (p = 0.049, R2 = 0.197). There was also a borderline negative correlation between MLH and the sum of rest pressures (p = 0.09, R2 = 0.15). AP/LR ratio was negatively correlated with the sum of squeeze pressures (p = 0.056, R2 = 0.197). LP-PS distances, both while at rest and during squeeze, were negatively correlated with the vaginal squeeze pressure (p = 0.046, R2 = 0.21; p = 0.011, R2 = 0.31, respectively). LP-V distance, both at rest and during squeeze, was negatively correlated with the sum of squeeze pressures on four vaginal walls (p = 0.02, R2 = 0.25; p = 0.005, R2 = 0.36, respectively).
Conclusions:
Stronger levator ani muscles, smaller MLH area and a more oval shape of pelvic floor hiatus as assessed by pelvic floor ultrasound are associated with higher squeeze vaginal pressures as assessed by 3D manometry.
More Related Videos
07:41Quantification of Levator Ani Hiatus Enlargement by Magnetic Resonance Imaging in Males and Females with Pelvic Organ Prolapse
Published on: April 17, 2019
09:59Biaxial Basal Tone and Passive Testing of the Murine Reproductive System Using a Pressure Myograph
Published on: August 13, 2019
Related Concept Videos
Urodynamic Studies: Uroflowmetry
Imaging Studies VI: Voiding Cystourethrography and Cystography
Muscles of the Pelvic Floor and Perineum
Perineal Layer
The perineum is a diamond-shaped area below the pelvic diaphragm, divided into an anterior urogenital triangle that contains the external genitals and a posterior anal triangle housing the anus. The urogenital...
Imaging Studies II: Ultrasonography
Nursing Assessment of the Genitourinary System III: Percussion and Auscultation
Assessment of the Abdomen II: Percussion
Percussion
Percussion is an essential...