Related Experiment Video
Updated: Oct 1, 2025

Experimental Protocol to Determine the Chloride Threshold Value for Corrosion in Samples Taken from Reinforced Concrete Structures
Published on: August 31, 2017
Detection of initiation of corrosion induced damage in concrete structures using nonlinear ultrasonic techniques
Thirumalaiselvi Arumaikani1, Saptarshi Sasmal1, Tribikram Kundu2
1Special and Multi-functional Structures Laboratory, Council of Scientific and Industrial Research-Structural Engineering Research Centre, Chennai 600113, India.
Abstract:
Structural failure caused by corrosion of the reinforcing steel in concrete structures is quite common. In most cases, corrosion cracks appear on the surface at a late stage, leaving inadequate time for taking any measures. This paper investigates the detection of corrosion damage in reinforced concrete elements by using nonlinear ultrasonic (NLU) techniques. Various linear ultrasonic and NLU techniques were adopted to identify the most sensitive technique and ultrasonic parameters for corrosion induced damage detection at its early stage. It is observed that the linear techniques are not very effective in detecting corrosion induced damage. The sideband peak count-index (or SPC-I), a relatively new and promising technique, has been found to be an excellent indicator for the detection of corrosion induced damage initiation. However, its efficacy for detecting corrosion induced damage has not yet been reported. The present study shows that the SPC-I-based NLU technique outperforms (with the highest sensitivity) all other NLU techniques for detecting the onset of corrosion in steel and micro-crack formation in the surrounding material. As the corrosion progresses and cracks appear on the surface of the concrete, the efficiency of the SPC-I slowly weakens and other technique(s) are found to be quite efficient at that stage.
Related Concept Videos
Microcracking in Concrete
Corrosion of Reinforcement
However, over time and under certain conditions like carbonation, chloride ingress, and cracking this protective state can be compromised. Steel has areas with...
Non-destructive Tests for Concrete Strength
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Types of Non-structural Cracks in Concrete
Plastic shrinkage cracks typically form within hours after the concrete is poured. The concrete's surface dries faster than the bottom, creating tensile stress that the still-plastic concrete cannot withstand, leading to diagonal or randomly patterned cracks on the concrete surface.
Sulfate Attack on Concrete
Sulfates from sources like soil, groundwater, or industrial effluents...