Rapid On-Site Evaluation Technical Exercise Using Digital Pathology: Peer Comparison in an External Quality Assurance
Janelle Greaves1, Julia Pagliuso1, Jennifer Ross1
1The Royal College of Pathologists of Australasia Quality Assurance Programs (RCPAQAP), St Leonards, New South Wales, Australia.
Acta Cytologica
|March 2, 2022
Summary
External quality assurance for rapid on-site evaluation (ROSE) in cytopathology revealed variations in diagnostic adequacy and technical recommendations. This proficiency testing highlights the need for standardized procedures in ROSE for thyroid fine-needle aspiration biopsy samples.
Area of Science:
- Cytopathology
- External Quality Assurance (EQA)
- Diagnostic Pathology
Background:
- The Royal College of Pathologists of Australasia Quality Assurance Programs (RCPAQAP) offers external quality assurance (EQA) for pathology laboratories.
- A cytopathology technical program was established in 2018 to assess routine cytopreparatory techniques.
- The pilot focused on standard operating procedures and laboratory performance during rapid on-site evaluation (ROSE).
Purpose of the Study:
- To assess diagnostic adequacy and provide technical recommendations for thyroid fine-needle aspiration biopsy (FNAB) samples using whole slide images in a ROSE setting.
- To evaluate laboratory performance in routine cytopreparatory techniques.
- To identify variations in standard operating procedures and diagnostic feedback during ROSE.
Main Methods:
- Four whole slide imaging cases of Diff-QuikTM stained thyroid FNAB preparations were provided to RCPAQAP Cytopathology diagnostic program participants.
- Participating laboratories assessed on-site adequacy and provided technical recommendations.
- A laboratory practice questionnaire was also administered.
Main Results:
- 186 submissions were received across four virtual cases.
- Participant assessment of on-site adequacy showed high concordance in some cases.
- Variation was observed in initial diagnostic evaluation and technical recommendations.
Conclusions:
- Rapid on-site evaluation (ROSE) is a standard procedure globally but shows susceptibility to variation.
- Peer comparison in an EQA exercise highlighted inconsistencies in ROSE across standard operating procedures, diagnostic adequacy, feedback, and recommendations.
- Standardization of ROSE procedures is crucial for consistent diagnostic quality.