Related Experiment Video
Updated: Oct 1, 2025

Orthopedic Robot-Assisted Femoral Neck System in the Treatment of Femoral Neck Fracture
Published on: March 3, 2023
Femoral prosthesis neck fracture following total hip arthroplasty - a systematic review
P G van Doesburg1, E J van Langelaan2, I Apachitei2
1Department of Orthopaedic Surgery, Alrijne Hospital Leiderdorp, Simon Smitweg 1, 2353GA, Leiderdorp, The Netherlands. pgdoesburg@alrijne.nl.
Purpose:
Head-neck modularity was introduced into total hip arthroplasty to provide more intraoperative surgical options. However, modularity led to new problems, such as trunnionosis and fractures of the femoral prosthesis neck. The purpose of this study was to identify risk factors for hip neck fractures and to provide recommendations to prevent damage and fractures of the neck.
Methods:
A systematic review of the literature was performed according to the PRISMA guidelines.
Results:
Thirty-three case studies were included. Methodologically, most included studies were of moderate or good quality. The 80 neck fractures included in the review took place, on average, 7 years after stem placement. Male gender, high body weight, obesity, previous revision surgery, mixing components from different manufacturers, use of long skirted heads, cobalt-chromium (large size) heads were identified as potential risk factors.
Conclusion:
Hip neck fractures occur on average 7 years after stem placement. The etiology of hip neck fractures is multifactorial. This review revealed several preventable implant- and surgeon-related risk factors.