Related Experiment Video
Updated: Oct 1, 2025

Insertion, Maintenance, and Removal of the Percutaneous Dual Lumen Cannula Right Ventricular Assist Device
Published on: July 20, 2022
Comprehensive Monitoring in Patients With Dual Lumen Right Atrium to Pulmonary Artery Right Ventricular Assist Device
Asad A Usman1, Audrey E Spelde1, Michael Ibrahim2
1From the Anesthesiology and Critical Care, Department of Anesthesiology and Critical Care, University of Pennsylvania, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania.
Abstract:
Right ventricular assist devices (RVADs) can be used in patients with acute right heart failure. A novel device that has recently been deployed is the right atrium to pulmonary artery (RA-PA) dual lumen single cannula (DLSC). One of the limitations is that it occupies a large proportion of the right ventricular outflow tract and PA; therefore, standard continuous hemodynamic monitoring with a pulmonary artery catheter is commonly not used. Serial echocardiography is pivotal for device deployment, monitoring device position, assessing RV readiness for decannulation, and surveilling for short-term complications. We performed a retrospective case series of 24 patients with RA-PA DLSC RVAD assessing echocardiographic RV progression and vasoactive infusion requirements. The overall survival was 66.6%. The average vasoactive infusion score at the time of cannulation was 24.9 ± 43.9, at decannulation in survivors 4.6 ± 4.9 vs . 25.4 ± 21.5 in nonsurvivors, and 2.7 ± 4.9 at 48 hours post decannulation. On echocardiography, the average visual estimate of RV systolic function encoded (0 = none and 5 = severe) in survivors was 3.9 ± 1.2, 2.8 ± 1.6, 2.5 ± 1.7, and 2.8 ± 1.9, respectively, and in nonsurvivors 3.8 ± 1.6 and 3.4 ± 1.8, respectively. This demonstrated an RV systolic function improvement over time in survivors as opposed to nonsurvivors. This was also demonstrated in RV size visual estimate, respectively. Quantitatively, at the predefined four timepoints, the RV:LV, tricuspid annular plane systolic excursion, and fractional area change all improve over time and there is statistically significant difference in survivors versus nonsurvivors. In this study, we describe a cohort of patients treated with RA-PA DLSC RVAD. We illustrate the critical nature of echocardiographic measures to rate the progression of RV function, improvement in vasoactive infusion requirements, and ventilator parameters with the RA-PA DLSC.
More Related Videos
08:12Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS
Published on: November 26, 2018
03:40Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Cardiomyopathy V: Interprofessional Care
Cardiomyopathy II: Dilated Cardiomyopathy
Mitral Stenosis IV: Nursing Management