Bladder filling in patients undergoing prostate radiotherapy on a MR-linac: The dosimetric impact
Gillian Adair Smith1, Alex Dunlop1,2, Helen Barnes1
1Royal Marsden NHS Foundation Trust, United Kingdom.
Abstract:
The implementation of adaptive radiotherapy for prostate cancer compensates for inter-fraction motion, at the penalty of increased time in room. The subsequent increase in bladder filling may impact dosimetry, which we have investigated on ten patients treated on the MR-linac. Patients drank water before treatment, to achieve a bladder volume of 200-300 cm3. Bladder and bowel were re-outlined offline on 140 images and plans recalculated. All mandatory bladder dose constraints and 99.1% of bowel constraints were achieved at time of treatment, despite varying bladder volumes and varying adherence to original bladder filling guidance.