Jarcy Zee1,2, Daniel Muenz3, Keith P McCullough3
1Department of Biostatistics, Epidemiology, and Informatics, University of Pennsylvania, Philadelphia, Pennsylvania.
Rationale & Objective:
Potential surrogate end points for kidney failure have been proposed in chronic kidney disease (CKD); however, they must be evaluated to ensure accurate, powerful, and harmonized research, particularly among patients with advanced CKD. The aim of the current study was to investigate the power and predictive ability of surrogate kidney failure end points in a population with moderate-to-advanced CKD.
Study Design:
Analysis of longitudinal data of a large multinational CKD observational study (Chronic Kidney Disease Outcomes and Practice Patterns Study).
Setting & Participants:
CKD stage 3-5 patients from Brazil, France, Germany, and the United States.
Outcomes:
Reaching an estimated glomerular filtration rate (eGFR) < 15 mL/min/1.73 m2 or eGFR decline of ≥40%, and composite end points of these individual end points.
Analytical Approach:
Each end point was used as a time-varying indicator in the Cox model to predict the time to kidney replacement therapy (KRT; dialysis or transplant) and was compared by the number of events and prediction accuracy.
Results:
8,211 patients had a median baseline eGFR of 27 mL/min/1.73 m2 (interquartile range, 21-36 mL/min/1.73 m2) and 1,448 KRT events over a median follow-up of 2.7 years (interquartile range, 1.2-3.0 years). Among CKD stage 4 patients, the eGFR < 15 mL/min/1.73 m2 end point had higher prognostic ability than 40% eGFR decline, but the end points were similar for CKD stage 3 patients. The combination of eGFR < 15 mL/min/1.73 m2 and 40% eGFR decline had the highest prognostic ability for predicting KRT, regardless of the CKD stage. Including KRT in the composite can increase the number of events and, therefore, the power.
Limitations:
Variable visit frequency resulted in variable eGFR measurement frequency.
Conclusions:
The composite end point can be useful for CKD progression studies among patients with advanced CKD. Harmonized use of this approach has the potential to accelerate the translation of new discoveries to clinical practice by identifying risk factors and treatments for kidney failure.
More Related Videos
Related Concept Videos
Chronic Kidney Disease I: Introduction
Chronic Kidney Disease III: Interprofessional Care
Kidney Transplant I: Introduction
Acute Kidney Injury IV: Diagnostic Studies and Prevention
Acute Kidney Injury III: Clinical Manifestations
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...