Related Experiment Video
Updated: Oct 1, 2025

Safety Precautions and Operating Procedures in an ABSL-4 Laboratory: 4. Medical Imaging Procedures
Published on: October 3, 2016
Fast radiological safety evaluation applied to maintenance in cargo and container inspection facilities
Samuel Q Pelegrineli1,2, Ademir X Silva1, Wilson Ss Filho3
1Graduate Program in Nuclear Engineering, 28125Federal University of Rio de Janeiro, Brazil.
Abstract:
The application of nuclear technologies in a cargo and container inspection facility can increase the risk of accidents. Estimating the radiation dose in the controlled area generates critical information for elaborating routines aimed at establishing more effective safety procedures. For radiological protection purposes, mapping ambient dose equivalent H*(10) levels is crucial. The radiation source used was a fixed linear accelerator of 4.5 MeV. Five RadEye PRD-ER (Thermo Fisher Scientific) personal radiation monitors and five Geiger-Müller MRAD 111 (Ultra Radac) personal radiation monitors were used for the radiation measurements. The highest ambient equivalent dose rate and dose per scan were found with the Geiger-Müller monitors at values of 5.76E-01 mSv/h and 1.12E-03 mSv, respectively. The results showed that for public individuals, the number of scans at the point of highest dose rate value cannot exceed 893-unit operations. Additionally, the risks involved in the abnormal situation (increased H*(10)) were estimated by using a model to predict the development of solid cancer as a result of occupational radiological exposure. This procedure highlights the risks involved, hence providing initial support to the decision process.
More Related Videos
09:18Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident
Published on: December 14, 2017
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
Published on: September 4, 2017
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...