Characteristics of the Maternal Jugular Venous Pulse Waveform by Combined Doppler-Electrocardiogram Assessment

Inge Dierickx1, Cécile Kremer2, Liesbeth Bruckers2

  • 1Department of Obstetrics and Gynaecology, Sint Lucas Ziekenhuis, Gent, Belgium; Department of Physiology, Hasselt University, Hasselt, Belgium.

Standardized combined Doppler-electrocardiogram assessment was performed longitudinally at three different locations of internal jugular veins between 12 wk of gestation and 6 wk postnatally in 24 uncomplicated pregnancies. All images were classified as typical or non-typical based on the presence of the physiologic deflections A, X, H and C. Linear mixed models with random intercepts of typical images were used to investigate gestational changes in venous pulse transit time and venous impedance index. Unequivocal identification of venous pulse transit time and venous impedance index was possible in 2617 of 3798 (69%) and 2234 of 3798 (59%) images, respectively. The best identification rate (80%, 1018/1266) was at the right distal internal jugular vein. Venous pulse transit time increased with gestational age at all locations; venous impedance index decreased at the right sided internal jugular vein. Maternal jugular venous pulse waveform by combined Doppler-electrocardiogram allows unequivocal identification of A-deflection and calculation of venous pulse transit time and venous impedance index in around two-thirds of assessments, with the highest success rate at the right distal internal jugular vein. Gestational evolutions of venous pulse transit time and venous impedance index are similar to those reported at the level of renal interlobar and hepatic veins.

Related Concept Videos

Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.7K
Assessment of apical pulse01:17

Assessment of apical pulse

Assessing the Apical Pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
1.3K
Assessment of apical radial pulse01:25

Assessment of apical radial pulse

Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
905
Assessment of radial pulse01:11

Assessment of radial pulse

Assessment of Radial Pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
1.0K