Related Experiment Video
Updated: Oct 1, 2025

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Non-invasive Ventilation: Effect of Vented and Non-vented Exhalation Systems on Inspiratory CO2 and O2
Karl-Josef Franke1,2, Maik Schroeder3, Ulrike Domanski3
1Witten/Herdecke University, Alfred-Herrhausen-Straße 50, 58455, Witten, Germany. Karl-Josef.Franke@Klinikum-Luedenscheid.de.
Introduction:
To increase CO2 elimination and to reduce work of breathing in hypercapnic patients, non-invasive ventilation (NIV) can be applied via mask either with non-vented CO2 exhalation systems or with vented systems with leak port. The effect of the exhalation system on CO2 rebreathing in the mask and total gas exchange remains widely unknown. Aim of this study was to compare the exhalation systems in terms of inspiratory O2 and CO2 concentrations, breathing patterns and gas exchange.
Methods:
We prospectively examined 10 healthy subjects and 10 hypercapnic patients with both exhalation systems. O2 and CO2 were measured in the nose, in the mask, and in the ventilation circuit, and respiratory rate, tidal volume, and transcutaneous capnometry (PtcCO2) were recorded during the experiments.
Results:
Using the non-vented system, CO2 concentrations in the mask were significantly higher in both subject groups, and PtcCO2 values in the patient group increased up to 3.6 mmHg compared to the vented system (p = 0.011). O2 concentrations increased with higher O2 flow rates, but were significantly lower in the vented settings in both groups. No effect in breathing pattern could be demonstrated during the measurement time.
Conclusion:
Using NIV, the chosen exhalation system influences CO2 and O2 concentrations under the mask, CO2 rebreathing from the mask and could influence the effectiveness of the ventilation support with regards to hypercapnia treatment. To compensate for relevant hypoxia, the O2 supplementation must be set up to a sufficient level under a vented system.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: