Related Experiment Video
Updated: Oct 1, 2025

Evaluating Regional Pulmonary Deposition using Patient-Specific 3D Printed Lung Models
Published on: November 11, 2020
A Quantitative Study of Particle Dispersion due to Respiratory Support Modalities in PC-12 Aircraft: Prehospital
Michael B Peddle1, Hamed Avari2, Justin A Smith3
1Ornge, Mississauga, Ontario, Canada; Division of Emergency Medicine, Western University, Victoria Hospital, London, Ontario, Canada.
Objective:
It is unclear whether supplemental oxygen and noninvasive ventilation respiratory support devices increase the dispersion of potentially infectious bioaerosols in a pressurized air medical cabin. This study quantitatively compared particle dispersion from respiratory support modalities in an air medical cabin during flight.
Methods:
Dispersion was measured in a fixed wing air ambulance during flight with a breathing medical mannequin simulator exhaling nebulized saline from the lower respiratory tract with the following respiratory support modalities: a nasal cannula with a surgical mask, high-flow nasal oxygen (HFNO) with a surgical mask, and noninvasive bilevel positive airway pressure (BiPAP) ventilation.
Results:
Nasal cannula oxygen with a surgical mask was associated with the highest particle concentrations. In the absence of mask seal leaks, BiPAP was associated with 1 order of magnitude lower particle concentration compared with a nasal cannula with a surgical mask. Particle concentrations associated with HFNO with a surgical mask were lower than a nasal cannula with a surgical mask but higher than BiPAP.
Conclusions: