[Ascending Aorta and Aortic Valve Replacement in Unicuspid Aortic Valve:Report of a Case]
Masaki Yada1, Uhito Yuasa, Takuya Komada
1Department of Cardiovascular Surgery, Kuwana City Medical Center, Kuwana, Japan.
Abstract:
A 53-year-old male was admitted to our hospital due to severe aortic stenosis and mild aortic regurgitation. The patient had no heart failure symptoms, but aortic stenosis progressed year by year. Aortic valve dysfunction caused by unicuspid aortic valve (UAV). Intraoperative transesophageal echocardiography contributed to diagnose UAV, three-dimentional echocardiographic imaging can be used for better evaluation. Intraoperative finding showed one open commissure between the left- and non-coronary cusp position, and this shape of valve is classified unicommissural unicuspid aortic valve. Also ascending aortic dilatation was found in this case, we replaced both ascending aorta and aortic valve. The postoperative course was uneventful. We report a very rare case of unicuspid aortic valve including aortic dilatation.