Anaïs Debucquois1,2, Vincenzo Vento1,2, Nicole Neumann1
1Groupe Européen de Recherche sur les Prothèses Appliquées à la Chirurgie Vasculaire, University Hospital of Strasbourg, Strasbourg, France.
Objective:
To ascertain whether simulated endovascular procedures are comparable to real life operating room (OR) procedures, particularly with regard to irradiation time.
Methods:
This was a retrospective study comparing simulation with clinical data. Fluoroscopy time and overall operation time were compared between simulated abdominal aortic endovascular repair (EVAR) and iliac procedures that were performed, respectively, from 2016 to 2019 and from 2015 to 2019, and clinical EVAR and iliac procedures performed in the OR between January 2018 and November 2021.
Results:
Within the defined periods, 171 simulated procedures (91 EVAR, 80 iliac) and 199 clinical procedures (111 EVAR, 88 iliac) were performed. For both EVAR and iliac procedures, median total procedure time was much longer during real surgery (p < .001). However, median total fluoroscopy time remained the same, whether the procedure was real surgery or performed on the simulator, for iliac procedures (8.47 minutes in the OR, 8.35 minutes on the simulator, p = .61) and for EVAR procedures (14.80 minutes in the OR, 15.00 minutes on the simulator p = .474).
Conclusion:
Simulated endovascular procedures are comparable with real life OR procedures, particularly with regard to irradiation time when integrated in a dedicated curriculum.
Related Concept Videos
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...