Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
Comparison of L1 CT-attenuation and cortical thickness in predicting osteoporosis by opportunistic CT
Qianqian Yao1, Jiaojiao Liu1, Kemei Yuan1
1Department of Radiology, The Second Affiliated Hospital of Shandong First Medical University, Taian, Shandong, China.
Background:
In vertebrae, the amount of cortical bone has been estimated at 30-60%, but 45-75% of axial load on a vertebral body is borne by cortical bone.
Objective:
To compare the role of L1 CT-attenuation and cortical thickness in predicting osteoporosis by opportunistic CT and explore cortical thickness value in osteoporosis.
Methods:
We collected data of 94 patients who underwent DXA and thoracic and/or abdominal CT to demonstrate an entire L1 for other indications in routine practice. Patients were divided into three groups according to T-score: osteoporosis, osteopenia, or normal. CT-attenuation value and cortical thickness of L1 were measured. ANOVA analysis was utilized to analyze CT-attenuation and cortical thickness among the three groups. Sensitivity, specificity, and area under the curve (AUC) predicting low BMD were determined using ROC. Pearson correlations were employed to describe relationship between L1 BMD and CT-attenuation value, BMD, as well as cortical thickness.
Results:
The mean cortical thickness was 0.83±0.11, 0.72±0.10, and 0.64±0.09 mm for normal, osteopenia, and osteoporotic subgroups, respectively. A statistically significant difference was observed in cortical thickness and CT-attenuation value among these three subgroups. A mean CT-attenuation value threshold of > 148.7 yielded 73.0% sensitivity and 86.0% specificity for distinguishing low BMD from normal with an AUC = 0.83. Pearson correlation analysis indicated that BMD was positively correlated with CT-attenuation (r = 0.666, P < 0.001) and cortical thickness (r = 0.604, P < 0.001).
Conclusions:
L1 CT-attenuation and cortical thickness measured on opportunistic CT can help predict osteoporosis. Compared with cortical thickness, CT-attenuation is a more sensitive and accurate index for distinguishing low BMD from normal.
More Related Videos
07:12Semiautomated Longitudinal Microcomputed Tomography-based Quantitative Structural Analysis of a Nude Rat Osteoporosis-related Vertebral Fracture Model
Published on: September 28, 2017
06:59Author Spotlight: An Economic and Efficient Method for Quantitative Evaluation of Bone Microarchitecture in a Murine Osteoporosis Model
Published on: September 8, 2023
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies III: Computed Tomography